Spectral analysis of dynamic long-axial-field-of-view PET studies: a flexible framework for whole-body multi-organ kinetic quantification

Objective. Although long-axial-field-of-view (LAFOV) PET systems are increasingly installed worldwide, quantitative analysis of dynamic LAFOV PET remains largely based on compartmental models or graphical methods. This study systematically evaluates and adapts spectral analysis (SA) as a flexible, data-driven framework for multi-organ kinetic quantification. Approach.SA represents the tissue impulse response function as a non-negative combination of exponential components without requiring a predefined compartmental structure. Four implementations were investigated: standard SA, SA with tracer arrival delay correction (SA*), spectral analysis with iterative filter (SAIF), and SAIF with delay correction (SAIF*). The methods were evaluated at both volume of interest (VOI) and voxel levels using dynamic 18F-FDG PET/CT data from 24 cancer patients, including 40 tumor lesions. Main results. Delay correction improved early-phase time activity curve (TAC) fitting and reduced Akaike information criterion (AIC) values across most organs. SA* achieved comparable or better fitting performance than two-tissue compartmental model with delay correction (2C*) in several regions without requiring a predefined compartmental structure. Kinetic parameter estimates showed the highest consistency for Ki, while K1, VT, and vascular contributions exhibited greater method-dependent variability. The resulting spectra revealed distinct kinetic patterns across normal organs and individual tumors. At the voxel level, SA* generated acceptable parametric images without iterative filtering, while SAIF* provided additional signal-to-noise ratio (SNR) improvements, particularly in some tumor regions. Significance. This first systematic evaluation demonstrates the potential of SA for multi-organ kinetic quantification with dynamic LAFOV PET. Its flexible kinetic representation may be particularly valuable for investigating novel diagnostic and theranostic radiotracers whose whole-body kinetic behavior is not yet fully characterized.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-11-25
DOI
https://doi.org/10.1088/1361-6560/aec6ec
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Spectral analysis of dynamic long-axial-field-of-view PET studies: a flexible framework for whole-body multi-organ kinetic quantification

Fengyun Gu, Ruiqing Ni, Axel Rominger, Kuangyu Shi et al.
4 links
Physics in Medicine and Biology
Medical Imaging Techniques and Applications
article

Spectral analysis of dynamic long-axial-field-of-view PET studies: a flexible framework for whole-body multi-organ kinetic quantification

Fengyun Gu, Ruiqing Ni, Axel Rominger, Kuangyu Shi, Qi Wu, Shen Ni, Terry Jones
article en

Abstract

Objective. Although long-axial-field-of-view (LAFOV) PET systems are increasingly installed worldwide, quantitative analysis of dynamic LAFOV PET remains largely based on compartmental models or graphical methods. This study systematically evaluates and adapts spectral analysis (SA) as a flexible, data-driven framework for multi-organ kinetic quantification. Approach.SA represents the tissue impulse response function as a non-negative combination of exponential components without requiring a predefined compartmental structure. Four implementations were investigated: standard SA, SA with tracer arrival delay correction (SA*), spectral analysis with iterative filter (SAIF), and SAIF with delay correction (SAIF*). The methods were evaluated at both volume of interest (VOI) and voxel levels using dynamic 18F-FDG PET/CT data from 24 cancer patients, including 40 tumor lesions. Main results. Delay correction improved early-phase time activity curve (TAC) fitting and reduced Akaike information criterion (AIC) values across most organs. SA* achieved comparable or better fitting performance than two-tissue compartmental model with delay correction (2C*) in several regions without requiring a predefined compartmental structure. Kinetic parameter estimates showed the highest consistency for Ki, while K1, VT, and vascular contributions exhibited greater method-dependent variability. The resulting spectra revealed distinct kinetic patterns across normal organs and individual tumors. At the voxel level, SA* generated acceptable parametric images without iterative filtering, while SAIF* provided additional signal-to-noise ratio (SNR) improvements, particularly in some tumor regions. Significance. This first systematic evaluation demonstrates the potential of SA for multi-organ kinetic quantification with dynamic LAFOV PET. Its flexible kinetic representation may be particularly valuable for investigating novel diagnostic and theranostic radiotracers whose whole-body kinetic behavior is not yet fully characterized.

Physics in Medicine and Biology
University of Bern (CH), North China Electric Power University (CN), University College Cork (IE), University of California, Davis (US)
European Regional Development Fund, Fundamental Research Funds for the Central Universities
Good health and well-being
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon