Condition Assessment of Field-Aged Composite Insulators Following Incidents of Insulator Flashunder

A condition assessment of a group of field-aged insulators operated for only 6 years on the island of Rhodes after incidents of intense electrical activity is presented in this paper. The investigated insulators were in service in 150 kV overhead transmission lines operating in proximity to the seacoast, exposed to the action of marine pollution. Although the same type of insulator has been widely used in similar conditions, both on the island of Rhodes and on the island of Crete, incidents of intense electrical activity have only been experienced in a specific area on the southwest side of Rhodes. To understand the deterioration mechanism, in addition to a group of failed insulators, a number of insulators from the same area without indication of deterioration were removed to be tested. In total, 40 insulators were examined: 23 with extensive failure, three without any deterioration and 14 with different levels of tracking and erosion traces along the polymeric housing. A series of tests were performed, including visual inspection, hydrophobicity classification, insulation performance through tanδ measurements, an adhesion test between the polymeric housing and the rod and material identification of the housing material through FTIR-ATR. The results indicate that the main failure mechanism is insulator flashunder due to the poor adhesion between the polymeric housing and the rod, as well as the poor sealing of insulators, favoring the ingress of water on the insulator rod and the initiation of electrical discharges.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-05-12
DOI
https://doi.org/10.3390/en19102325
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Condition Assessment of Field-Aged Composite Insulators Following Incidents of Insulator Flashunder

Nikolaos Mavrikakis, Kiriakos Siderakis
Energies
High voltage insulation and dielectric phenomena
article

Condition Assessment of Field-Aged Composite Insulators Following Incidents of Insulator Flashunder

Nikolaos Mavrikakis, Kiriakos Siderakis
article en

Abstract

A condition assessment of a group of field-aged insulators operated for only 6 years on the island of Rhodes after incidents of intense electrical activity is presented in this paper. The investigated insulators were in service in 150 kV overhead transmission lines operating in proximity to the seacoast, exposed to the action of marine pollution. Although the same type of insulator has been widely used in similar conditions, both on the island of Rhodes and on the island of Crete, incidents of intense electrical activity have only been experienced in a specific area on the southwest side of Rhodes. To understand the deterioration mechanism, in addition to a group of failed insulators, a number of insulators from the same area without indication of deterioration were removed to be tested. In total, 40 insulators were examined: 23 with extensive failure, three without any deterioration and 14 with different levels of tracking and erosion traces along the polymeric housing. A series of tests were performed, including visual inspection, hydrophobicity classification, insulation performance through tanδ measurements, an adhesion test between the polymeric housing and the rod and material identification of the housing material through FTIR-ATR. The results indicate that the main failure mechanism is insulator flashunder due to the poor adhesion between the polymeric housing and the rod, as well as the poor sealing of insulators, favoring the ingress of water on the insulator rod and the initiation of electrical discharges.

EnergiesVol. 19(10)
Mediterranean University (ME), Hellenic Mediterranean University (GR)
Life below water
Openalex Percentile: Top 11%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Condition Assessment of Field-Aged Composite Insulators Following Incidents of Insulator Flashunder — Nikolaos Mavrikakis, Kiriakos Siderakis · Energies (2026) | TGRS Research Map | TGRS