Comparison of crystalloid preloading and co-loading for the prevention of spinal induced-hypotension in elective cesarean delivery: a prospective cohort study

Background: Maternal hypotension is the most frequent complication of spinal anesthesia for cesarean delivery. In this study, we assessed the effect of crystalloid preloading versus co-loading on the incidence of spinal anesthesia-induced hypotension in parturients undergoing elective cesarean delivery. Method: An institutional-based prospective cohort study was conducted. A total of 90 participants were divided into three groups: 30 participants in preload group (G1) given 1000 ml of normal saline 15 minutes before spinal anesthesia, 30 participants in co-load group (G2) given 1000 ml of normal saline fluid within 15 minutes together with spinal anesthesia, and 30 participants in the control group (G3) who were not given preloading or co-loading fluids. Statistical analysis for the differences among the three groups was analyzed using a repeated measure multivariate analysis of variance (MANOVA) test. The Bonferonni post hoc test was used to compare the differences between the groups. Result: In the current study, systolic blood pressure, diastolic blood pressure, and mean arterial pressure significantly decreased among the control groups compared with the co-load and preload groups, P < 0.05. Vasopressor requirements were significantly decreased in the co-load group compared with preload and control groups, ( P = 0.043). The incidence of nausea and vomiting was also higher among control groups, ( P = 0.031). Conclusion: Based on the results of the current study, crystalloid fluid co-loading is more effective in reducing the incidence of hypotension after spinal anesthesia, reducing the need for a vasopressor and the occurrence of nausea and vomiting after spinal anesthesia in cesarean section parturients compared with preloading crystalloid fluid.

Authors

Institutions

Publication Details

Journal
Annals of Medicine and Surgery
Published
2026-05-12
DOI
https://doi.org/10.1097/ms9.0000000000005010
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of crystalloid preloading and co-loading for the prevention of spinal induced-hypotension in elective cesarean delivery: a prospective cohort study

Petros Baboker, Mulunesh Abebe, Haile Demissie, Ermias Assefa et al.
Annals of Medicine and Surgery
Hemodynamic Monitoring and Therapy
article

Comparison of crystalloid preloading and co-loading for the prevention of spinal induced-hypotension in elective cesarean delivery: a prospective cohort study

Petros Baboker, Mulunesh Abebe, Haile Demissie, Ermias Assefa, Ephrem Solomon, Kelil Musa, Natnael Tesfaye, Dula Ababa, Dejene Gulilat
article en

Abstract

Background: Maternal hypotension is the most frequent complication of spinal anesthesia for cesarean delivery. In this study, we assessed the effect of crystalloid preloading versus co-loading on the incidence of spinal anesthesia-induced hypotension in parturients undergoing elective cesarean delivery. Method: An institutional-based prospective cohort study was conducted. A total of 90 participants were divided into three groups: 30 participants in preload group (G1) given 1000 ml of normal saline 15 minutes before spinal anesthesia, 30 participants in co-load group (G2) given 1000 ml of normal saline fluid within 15 minutes together with spinal anesthesia, and 30 participants in the control group (G3) who were not given preloading or co-loading fluids. Statistical analysis for the differences among the three groups was analyzed using a repeated measure multivariate analysis of variance (MANOVA) test. The Bonferonni post hoc test was used to compare the differences between the groups. Result: In the current study, systolic blood pressure, diastolic blood pressure, and mean arterial pressure significantly decreased among the control groups compared with the co-load and preload groups, P < 0.05. Vasopressor requirements were significantly decreased in the co-load group compared with preload and control groups, ( P = 0.043). The incidence of nausea and vomiting was also higher among control groups, ( P = 0.031). Conclusion: Based on the results of the current study, crystalloid fluid co-loading is more effective in reducing the incidence of hypotension after spinal anesthesia, reducing the need for a vasopressor and the occurrence of nausea and vomiting after spinal anesthesia in cesarean section parturients compared with preloading crystalloid fluid.

Annals of Medicine and Surgery
Madda Walabu University (ET), Wollega University (ET), Wolkite University (ET), Ambo University (ET), Arba Minch University (ET)
Good health and well-being
Openalex Percentile: Top 5%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.