Research on an Improved Evaluation Method and Improvement Strategy for the Transportation Capacity of Submarine Cable in a Directional Drilling Section

The submarine cable installed in the directional drilling pipeline may face constrained ampacity due to the narrow air gap and complex thermal environment. The current studies have overlooked the axial heat transfer caused by variable burial depth and the influence of deep ground temperature, resulting in inaccurate assessment of the hot spot temperature and hot spot location of submarine cable in the directional drilling pipeline. To address this issue, the distributed parameter electrical circuit model for long-distance submarine cable and the three-dimensional thermal simulation model for the submarine cable landing section were developed to analyze the heat generation and dissipation characteristics of submarine cable in the directional drilling pipeline. Then, the hot spot location of submarine cable in the directional drilling pipeline was identified. Subsequently, an improved thermal rating method based on the quasi-three-dimensional thermal model was proposed to rapidly assess the hot spot temperature for the submarine cable in the directional drilling pipeline. The accuracy of the improved thermal rating method was verified by comparison with the simulation method. Finally, implementation of water circulation was conducted to resolve the overheating issue in the directional drilling pipeline. The investigations in this paper can provide support for the efficient utilization of submarine cable. The improved evaluation method for submarine cable in a directional drilling section proposed in this paper can be regarded as the supplement to the traditional IEC method.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-05-12
DOI
https://doi.org/10.3390/en19102320
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on an Improved Evaluation Method and Improvement Strategy for the Transportation Capacity of Submarine Cable in a Directional Drilling Section

G Liu, Ziheng Gao, Honglei Deng, Yiqun Chen et al.
Energies
Thermal Analysis in Power Transmission
article

Research on an Improved Evaluation Method and Improvement Strategy for the Transportation Capacity of Submarine Cable in a Directional Drilling Section

G Liu, Ziheng Gao, Honglei Deng, Yiqun Chen, Hanbo Dan, Fei Teng, Kun Huang, Junyao Le, Yuze Lei
article en

Abstract

The submarine cable installed in the directional drilling pipeline may face constrained ampacity due to the narrow air gap and complex thermal environment. The current studies have overlooked the axial heat transfer caused by variable burial depth and the influence of deep ground temperature, resulting in inaccurate assessment of the hot spot temperature and hot spot location of submarine cable in the directional drilling pipeline. To address this issue, the distributed parameter electrical circuit model for long-distance submarine cable and the three-dimensional thermal simulation model for the submarine cable landing section were developed to analyze the heat generation and dissipation characteristics of submarine cable in the directional drilling pipeline. Then, the hot spot location of submarine cable in the directional drilling pipeline was identified. Subsequently, an improved thermal rating method based on the quasi-three-dimensional thermal model was proposed to rapidly assess the hot spot temperature for the submarine cable in the directional drilling pipeline. The accuracy of the improved thermal rating method was verified by comparison with the simulation method. Finally, implementation of water circulation was conducted to resolve the overheating issue in the directional drilling pipeline. The investigations in this paper can provide support for the efficient utilization of submarine cable. The improved evaluation method for submarine cable in a directional drilling section proposed in this paper can be regarded as the supplement to the traditional IEC method.

EnergiesVol. 19(10)
Zhejiang Energy Group (China) (CN), China Power Engineering Consulting Group (China) (CN), South China University of Technology (CN)
China Postdoctoral Science Foundation, China Power Engineering Consulting Group, Basic and Applied Basic Research Foundation of Guangdong Province
Openalex Percentile: Top 6%
Thermal Analysis in Power Transmission
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.