External benchmarking of lung ultrasound models for pneumothorax‐related signs: A manifest‐based multi‐source study

Abstract Background and aims Reproducible external benchmarks for pneumothorax‐related lung ultrasound (LUS) AI are scarce, and binary lung‐sliding classification may obscure clinically important signs. We therefore developed a manifest‐based external benchmark and used it to test both cross‐domain generalisation and task validity. Methods We curated 280 clips from 190 publicly accessible LUS source videos and released a reconstruction manifest containing URLs, timestamps, crop coordinates, labels, and probe shape. Labels were normal lung sliding, absent lung sliding, lung point, and lung pulse. A previously published single‐site binary classifier was evaluated on this benchmark; challenge‐state analysis examined lung point and lung pulse using the predicted probability of absent sliding, P(absent). Results The single‐site comparator achieved Receiver Operating Characteristic–Area Under the Curve (ROC‐AUC) 0.9625 in‐domain but 0.7050 on the heterogeneous external benchmark; restricting external evaluation to linear clips still yielded ROC‐AUC 0.7212. In challenge‐state analysis, mean P(absent) ranked absent (0.504) > lung point (0.313) > normal (0.186) > lung pulse (0.143). Lung pulse differed from absent clips ( p = 0.000470) but not from normal clips ( p = 0.813), indicating that the binary model treated pulse as normal‐like despite absent sliding. Lung point differed from both absent ( p = 0.000468) and normal ( p = 0.000026), supporting its interpretation as an intermediate ambiguity state rather than a clean binary class. Conclusion A manifest‐based, multi‐source benchmark can support reproducible external evaluation without redistributing source videos. Binary lung‐sliding classification is an incomplete proxy for pneumothorax reasoning because it obscures blind‐spot and ambiguity states, such as lung pulse and lung point.

Authors

Institutions

Publication Details

Journal
Clinical and Translational Discovery
Published
2026-05-12
DOI
https://doi.org/10.1002/ctd2.70152
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

External benchmarking of lung ultrasound models for pneumothorax‐related signs: A manifest‐based multi‐source study

Takehiro Ishikawa
Clinical and Translational Discovery
Ultrasound in Clinical Applications
article

External benchmarking of lung ultrasound models for pneumothorax‐related signs: A manifest‐based multi‐source study

Takehiro Ishikawa
article en

Abstract

Abstract Background and aims Reproducible external benchmarks for pneumothorax‐related lung ultrasound (LUS) AI are scarce, and binary lung‐sliding classification may obscure clinically important signs. We therefore developed a manifest‐based external benchmark and used it to test both cross‐domain generalisation and task validity. Methods We curated 280 clips from 190 publicly accessible LUS source videos and released a reconstruction manifest containing URLs, timestamps, crop coordinates, labels, and probe shape. Labels were normal lung sliding, absent lung sliding, lung point, and lung pulse. A previously published single‐site binary classifier was evaluated on this benchmark; challenge‐state analysis examined lung point and lung pulse using the predicted probability of absent sliding, P(absent). Results The single‐site comparator achieved Receiver Operating Characteristic–Area Under the Curve (ROC‐AUC) 0.9625 in‐domain but 0.7050 on the heterogeneous external benchmark; restricting external evaluation to linear clips still yielded ROC‐AUC 0.7212. In challenge‐state analysis, mean P(absent) ranked absent (0.504) > lung point (0.313) > normal (0.186) > lung pulse (0.143). Lung pulse differed from absent clips ( p = 0.000470) but not from normal clips ( p = 0.813), indicating that the binary model treated pulse as normal‐like despite absent sliding. Lung point differed from both absent ( p = 0.000468) and normal ( p = 0.000026), supporting its interpretation as an intermediate ambiguity state rather than a clean binary class. Conclusion A manifest‐based, multi‐source benchmark can support reproducible external evaluation without redistributing source videos. Binary lung‐sliding classification is an incomplete proxy for pneumothorax reasoning because it obscures blind‐spot and ambiguity states, such as lung pulse and lung point.

Clinical and Translational DiscoveryVol. 6(3)
Georgia Institute of Technology (US)
Openalex Percentile: Top 6%
Ultrasound in Clinical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.