Development of Channelized K/V Band Dicke Microwave Radiometer Based on SDR

With the rapid development of software-defined radio (SDR) technology, a digital, software-reconfigurable, and flexible solution is provided for microwave radiometers, particularly suitable for atmospheric water vapor and oxygen detection with wideband, multi-channel requirements, significantly improving system efficiency. Meanwhile, digitization helps improve channel consistency and address nonlinearity issues, while the digital zero-balancing mechanism implemented through adaptive integration is more suitable for digital platforms. This paper proposes a digital Dicke-type radiometer system based on an SDR platform, using Xilinx RFSoC XCZU47DR (AMD, San Jose, CA, USA) as the core hardware to achieve single-chip integration of RF signal sampling, digital local oscillator generation, and signal processing. The system implements a 46-channel channelized receiver (23 channels each for K-band and V-band) on an FPGA using a polyphase filter bank. The prototype filters achieve 70 dB stopband attenuation and 0.5 dB passband ripple, with each polyphase branch requiring only 25 coefficients, significantly reducing hardware resource consumption. An adaptive integration method is proposed, where an adaptive switch controller dynamically adjusts the hot source injection time ratio by calculating the power difference between adjacent integration periods, enabling the Dicke zero-balancing mechanism to operate entirely in the digital domain. Furthermore, a complete hardware transfer model is established for three signal branches (antenna, hot source, and matched load), and full-chain calibration of all 46 channels is performed using a liquid nitrogen cold source, with calibration reliability verified through blackbody measurements. Experimental results demonstrate brightness temperature consistency better than 0.7 K, with a sensitivity of less than 0.15 K for the K-band and less than 0.21 K for the V-band at 1 s integration time.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-05-12
DOI
https://doi.org/10.3390/s26103059
Primary Topic
Soil Moisture and Remote Sensing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Channelized K/V Band Dicke Microwave Radiometer Based on SDR

Zhenzhen Liang, Shijie Yang, Peng Liu, Caiyun Wang et al.
Sensors
Soil Moisture and Remote Sensing
article

Development of Channelized K/V Band Dicke Microwave Radiometer Based on SDR

Zhenzhen Liang, Shijie Yang, Peng Liu, Caiyun Wang, Wei Guo
article en

Abstract

With the rapid development of software-defined radio (SDR) technology, a digital, software-reconfigurable, and flexible solution is provided for microwave radiometers, particularly suitable for atmospheric water vapor and oxygen detection with wideband, multi-channel requirements, significantly improving system efficiency. Meanwhile, digitization helps improve channel consistency and address nonlinearity issues, while the digital zero-balancing mechanism implemented through adaptive integration is more suitable for digital platforms. This paper proposes a digital Dicke-type radiometer system based on an SDR platform, using Xilinx RFSoC XCZU47DR (AMD, San Jose, CA, USA) as the core hardware to achieve single-chip integration of RF signal sampling, digital local oscillator generation, and signal processing. The system implements a 46-channel channelized receiver (23 channels each for K-band and V-band) on an FPGA using a polyphase filter bank. The prototype filters achieve 70 dB stopband attenuation and 0.5 dB passband ripple, with each polyphase branch requiring only 25 coefficients, significantly reducing hardware resource consumption. An adaptive integration method is proposed, where an adaptive switch controller dynamically adjusts the hot source injection time ratio by calculating the power difference between adjacent integration periods, enabling the Dicke zero-balancing mechanism to operate entirely in the digital domain. Furthermore, a complete hardware transfer model is established for three signal branches (antenna, hot source, and matched load), and full-chain calibration of all 46 channels is performed using a liquid nitrogen cold source, with calibration reliability verified through blackbody measurements. Experimental results demonstrate brightness temperature consistency better than 0.7 K, with a sensitivity of less than 0.15 K for the K-band and less than 0.21 K for the V-band at 1 s integration time.

SensorsVol. 26(10)
Chinese Academy of Sciences (CN), National Space Science Center (CN), University of Chinese Academy of Sciences (CN)
Openalex Percentile: Top 8%
Soil Moisture and Remote Sensing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.