Radiographic Healing and Observed Complications Following Light-Cured Polymer Immobilization: A Retrospective Cohort Study of 108 Patients

Purpose: Traditional plaster and fiberglass casts remain widely used for fracture immobilization but are associated with recognized challenges, including skin irritation, hygiene limitations, and distress during cast removal, particularly in pediatric populations. Light-cured polymer immobilization (LCPI) systems have been introduced as an alternative method of fracture support. The primary objective of this study was to describe radiographic healing and alignment outcomes among patients treated with an LCPI system. Secondary objectives were to document skin- and device-related events and to identify any unplanned removals or subsequent re-interventions. Methods: A 6-month retrospective cohort study was conducted involving 108 consecutive patients treated with an LCPI system between January and June 2025 at a single orthopaedic clinic. Clinical and radiographic records were reviewed to extract demographic information, injury characteristics, treatment details, immobilization duration, healing outcomes, alignment status, and recorded adverse events. Outcomes were summarized using descriptive statistics. Results: Immobilization was applied for 104 fractures (96.3%), three sprains (2.8%), and one elbow dislocation (0.9%). The cohort (76 males, 32 females; mean age: 13.4 years; range: 4–53) demonstrated radiographic union or progression toward union among fracture cases with available follow-up imaging. Mean immobilization duration was 29.2 days (SD: 6.2; range: 10–48). Alignment at device removal was documented as anatomic or near-anatomic in 103 of 104 fractures (99.1%) based on treating clinician assessment (99.1%). Device breakage was documented in 12 cases (11.1%), of which 3 required additional immobilization. Two patients (1.9%) experienced mild cutaneous reactions that resolved with conservative management. No severe device-related complications were documented. Conclusions: Healing outcomes and recorded adverse events were consistent with expected clinical patterns for this patient population in this descriptive retrospective cohort of patients treated with an LCPI system. These findings provide descriptive real-world data regarding clinical utilization and short-term outcomes in selected patients. Prospective comparative studies are needed to further define effectiveness, safety, cost considerations, and broader applicability across diverse fracture populations.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-05-12
DOI
https://doi.org/10.3390/jcm15103709
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radiographic Healing and Observed Complications Following Light-Cured Polymer Immobilization: A Retrospective Cohort Study of 108 Patients

James Stavitz, Ryan Porcelli, Viviana Negrón-Rodríguez, Onix Reyes Martínez et al.
Journal of Clinical Medicine
Bone fractures and treatments
article

Radiographic Healing and Observed Complications Following Light-Cured Polymer Immobilization: A Retrospective Cohort Study of 108 Patients

James Stavitz, Ryan Porcelli, Viviana Negrón-Rodríguez, Onix Reyes Martínez, Kenielle Olmeda-Mercado
article en

Abstract

Purpose: Traditional plaster and fiberglass casts remain widely used for fracture immobilization but are associated with recognized challenges, including skin irritation, hygiene limitations, and distress during cast removal, particularly in pediatric populations. Light-cured polymer immobilization (LCPI) systems have been introduced as an alternative method of fracture support. The primary objective of this study was to describe radiographic healing and alignment outcomes among patients treated with an LCPI system. Secondary objectives were to document skin- and device-related events and to identify any unplanned removals or subsequent re-interventions. Methods: A 6-month retrospective cohort study was conducted involving 108 consecutive patients treated with an LCPI system between January and June 2025 at a single orthopaedic clinic. Clinical and radiographic records were reviewed to extract demographic information, injury characteristics, treatment details, immobilization duration, healing outcomes, alignment status, and recorded adverse events. Outcomes were summarized using descriptive statistics. Results: Immobilization was applied for 104 fractures (96.3%), three sprains (2.8%), and one elbow dislocation (0.9%). The cohort (76 males, 32 females; mean age: 13.4 years; range: 4–53) demonstrated radiographic union or progression toward union among fracture cases with available follow-up imaging. Mean immobilization duration was 29.2 days (SD: 6.2; range: 10–48). Alignment at device removal was documented as anatomic or near-anatomic in 103 of 104 fractures (99.1%) based on treating clinician assessment (99.1%). Device breakage was documented in 12 cases (11.1%), of which 3 required additional immobilization. Two patients (1.9%) experienced mild cutaneous reactions that resolved with conservative management. No severe device-related complications were documented. Conclusions: Healing outcomes and recorded adverse events were consistent with expected clinical patterns for this patient population in this descriptive retrospective cohort of patients treated with an LCPI system. These findings provide descriptive real-world data regarding clinical utilization and short-term outcomes in selected patients. Prospective comparative studies are needed to further define effectiveness, safety, cost considerations, and broader applicability across diverse fracture populations.

Journal of Clinical MedicineVol. 15(10)
Ponce Health Sciences University (PR), Center for Children (US), Kean University (US), University of Puerto Rico at Arecibo (PR)
Openalex Percentile: Top 6%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.