Evaluation of a new system to determine wireless real-time skin temperature

Abstract To evaluate the body’s thermal status, it is essential to determine the mean skin temperature, ideally using wireless technology with real-time feedback. Such a system was not yet available. Therefore, the aim of current study was to examine the in- and ex-vivo validity and reliability of an innovative skin temperature sensor. New skin temperature sensors, named eTemp Performance, were developed with memory and direct read-out capabilities as an alternative to commonly used wireless iButton sensors that provide no real-time feedback. The time constant and precision of the sensors were evaluated by immersion in water baths and human experiments during exercise in the heat. The absolute skin temperature values measured with the eTemp Performance sensors and iButtons were compared to a calibrated gold standard with a variation during measurements of 0.12 °C. The time constant in water of the eTemp Performance sensors was 10.5 ± 1.1 s and 25.8 ± 3.3 s for the iButtons. The mean absolute offset from the standard was 0.06 ± 0.04 °C for the eTemp Performance sensors and 0.19 ± 0.03 °C for the iButtons ( p < 0.001). Human experiments showed no differences between eTemp Performance sensors and iButtons in mean skin temperature values during exercise in the heat. The eTemp Performance sensors are recommended for assessment of mean skin temperature determination since they have a response time in water that is 2.5 times shorter than that of the iButtons, a lower mean absolute offset from the standard than iButtons, and yield similar mean skin temperatures during exercise in the heat.

Authors

Institutions

Publication Details

Journal
Journal of Thermal Analysis and Calorimetry
Published
2026-05-11
DOI
https://doi.org/10.1007/s10973-026-15570-9
Primary Topic
Infrared Thermography in Medicine
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of a new system to determine wireless real-time skin temperature

Hashim Quraishi, Wouter D. van Marken Lichtenbelt, Hein A. M. Daanen, Lisa Klous et al.
Journal of Thermal Analysis and Calorimetry
Infrared Thermography in Medicine
article

Evaluation of a new system to determine wireless real-time skin temperature

Hashim Quraishi, Wouter D. van Marken Lichtenbelt, Hein A. M. Daanen, Lisa Klous, Coen C. W. G. Bongers, Nienke J. Haakma
article en

Abstract

Abstract To evaluate the body’s thermal status, it is essential to determine the mean skin temperature, ideally using wireless technology with real-time feedback. Such a system was not yet available. Therefore, the aim of current study was to examine the in- and ex-vivo validity and reliability of an innovative skin temperature sensor. New skin temperature sensors, named eTemp Performance, were developed with memory and direct read-out capabilities as an alternative to commonly used wireless iButton sensors that provide no real-time feedback. The time constant and precision of the sensors were evaluated by immersion in water baths and human experiments during exercise in the heat. The absolute skin temperature values measured with the eTemp Performance sensors and iButtons were compared to a calibrated gold standard with a variation during measurements of 0.12 °C. The time constant in water of the eTemp Performance sensors was 10.5 ± 1.1 s and 25.8 ± 3.3 s for the iButtons. The mean absolute offset from the standard was 0.06 ± 0.04 °C for the eTemp Performance sensors and 0.19 ± 0.03 °C for the iButtons ( p < 0.001). Human experiments showed no differences between eTemp Performance sensors and iButtons in mean skin temperature values during exercise in the heat. The eTemp Performance sensors are recommended for assessment of mean skin temperature determination since they have a response time in water that is 2.5 times shorter than that of the iButtons, a lower mean absolute offset from the standard than iButtons, and yield similar mean skin temperatures during exercise in the heat.

Journal of Thermal Analysis and Calorimetry
HAN University of Applied Sciences (NL), Radboud University Nijmegen (NL), Radboud University Medical Center (NL), Maastricht University (NL), Ministry of Defence (NL), Vrije Universiteit Amsterdam (NL)
ZonMw
Affordable and clean energy
Openalex Percentile: Top 5%
Infrared Thermography in Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.