Assessment of air handling unit to improve ventilation in congregate living settings: a multicenter cross-sectional study

BACKGROUND: Heating, ventilation, and air conditioning (HVAC) systems can modulate the risk of respiratory virus transmission. In congregate living settings (CLS), variability in the quality of this infrastructure presents an improvement opportunity. METHODS: We performed a cross-sectional study of the air handling units (AHU) of HVAC systems across a network of CLS to identify the most common problems and specific opportunities to improve ventilation. A third-party expert performed systematic HVAC assessments, which were analyzed based on presence and function of key AHU components to determine their association with air changes per hour (ACH) using a multivariable linear regression model. RESULTS: Across 15 participating CLS, the median ACH was 3.3 (IQR = 10.4) in common areas, 3.5 (IQR = 12.6) in resident rooms, and 6.6 (IQR = 9.7) in resident bathrooms. Closed outside air dampers and fans turned off was associated with decreased ACH in resident rooms (-9.5 ACH, 95% CI, -0.2 to -18.9) and resident washrooms (-7.0 ACH, 95% CI, -1.3 to -12.7). The absence of ducted air source was associated with decreased ACH in resident rooms (-12.2 ACH, 95% CI, -1.0 to -23.5). CONCLUSIONS: Across 15 CLS, we identified readily actionable targets for improvements to ventilation. Based on our findings, we propose assessment criteria to optimize the performance of existing AHU. Prospective studies evaluating the impact of a standardized approach to improving AHU on safety of CLS residents are needed.

Authors

Institutions

Publication Details

Journal
Infection Control and Hospital Epidemiology
Published
2026-05-11
DOI
https://doi.org/10.1017/ice.2026.10458
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of air handling unit to improve ventilation in congregate living settings: a multicenter cross-sectional study

Matthew Crittenden, Christina K. Chan, Charlie Tan, Heather Candon et al.
Infection Control and Hospital Epidemiology
Infection Control and Ventilation
article

Assessment of air handling unit to improve ventilation in congregate living settings: a multicenter cross-sectional study

Matthew Crittenden, Christina K. Chan, Charlie Tan, Heather Candon, Jerome A. Leis, Jeff Powis, James Callahan, Michael McRitchie
article en

Abstract

BACKGROUND: Heating, ventilation, and air conditioning (HVAC) systems can modulate the risk of respiratory virus transmission. In congregate living settings (CLS), variability in the quality of this infrastructure presents an improvement opportunity. METHODS: We performed a cross-sectional study of the air handling units (AHU) of HVAC systems across a network of CLS to identify the most common problems and specific opportunities to improve ventilation. A third-party expert performed systematic HVAC assessments, which were analyzed based on presence and function of key AHU components to determine their association with air changes per hour (ACH) using a multivariable linear regression model. RESULTS: Across 15 participating CLS, the median ACH was 3.3 (IQR = 10.4) in common areas, 3.5 (IQR = 12.6) in resident rooms, and 6.6 (IQR = 9.7) in resident bathrooms. Closed outside air dampers and fans turned off was associated with decreased ACH in resident rooms (-9.5 ACH, 95% CI, -0.2 to -18.9) and resident washrooms (-7.0 ACH, 95% CI, -1.3 to -12.7). The absence of ducted air source was associated with decreased ACH in resident rooms (-12.2 ACH, 95% CI, -1.0 to -23.5). CONCLUSIONS: Across 15 CLS, we identified readily actionable targets for improvements to ventilation. Based on our findings, we propose assessment criteria to optimize the performance of existing AHU. Prospective studies evaluating the impact of a standardized approach to improving AHU on safety of CLS residents are needed.

Infection Control and Hospital Epidemiology
Sunnybrook Health Science Centre (CA), Toronto East General Hospital (CA), Health Sciences Centre (CA), Health Net (US), Precision Research (United States) (US), National Patient Safety Foundation (US)
Industry, innovation and infrastructure
Openalex Percentile: Top 6%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.