Signal-to-noise ratio and spatial resolution characteristics of underwater time-gated SPAD array imaging systems

This study establishes comprehensive system signal-to-noise ratio and spatial resolution models for underwater time-gated (TG) imaging systems using single-photon avalanche diode (SPAD) arrays. Effects of water attenuation, target distance, and system parameters on detection range and spatial resolution are investigated, and corresponding optimization strategies are proposed. A complete underwater time-gated SPAD (TG-SPAD) array imaging system is constructed using a SPAD512S detector and experimentally validated, and a signal-to-noise ratio threshold of 2.5 is proposed for system performance evaluation. Results confirm high precision, with an average relative error of 2.90% between theoretical predictions and experimental measurements. This study offers theoretical guidance and technical support for the optimal design, evaluation, and applications of underwater TG-SPAD array imaging systems.

Authors

Institutions

Publication Details

Journal
Optics & Laser Technology
Published
2026-05-11
DOI
https://doi.org/10.1016/j.optlastec.2026.115481
Primary Topic
Advanced Optical Sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Signal-to-noise ratio and spatial resolution characteristics of underwater time-gated SPAD array imaging systems

Su Qiu, Weiqi Jin, Xiangzhi Yu, X Wang et al.
Optics & Laser Technology
Advanced Optical Sensing Technologies
article

Signal-to-noise ratio and spatial resolution characteristics of underwater time-gated SPAD array imaging systems

Su Qiu, Weiqi Jin, Xiangzhi Yu, X Wang, Shihao Zhu, Guanlin Wu
article en

Abstract

This study establishes comprehensive system signal-to-noise ratio and spatial resolution models for underwater time-gated (TG) imaging systems using single-photon avalanche diode (SPAD) arrays. Effects of water attenuation, target distance, and system parameters on detection range and spatial resolution are investigated, and corresponding optimization strategies are proposed. A complete underwater time-gated SPAD (TG-SPAD) array imaging system is constructed using a SPAD512S detector and experimentally validated, and a signal-to-noise ratio threshold of 2.5 is proposed for system performance evaluation. Results confirm high precision, with an average relative error of 2.90% between theoretical predictions and experimental measurements. This study offers theoretical guidance and technical support for the optimal design, evaluation, and applications of underwater TG-SPAD array imaging systems.

Optics & Laser TechnologyVol. 203
Beijing Institute of Optoelectronic Technology (CN)
National Natural Science Foundation of China
Life below water
Openalex Percentile: Top 5%
Advanced Optical Sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.