Outcomes of Variable-Angle Locking Anterior Patella Plating for the Treatment of OTA 34-C3 Patella Fractures

Abstract: ) treated at one multisite, urban, academic institution were identified. All fractures were classified as OTA 34-C3. The mean operating room time (wheels-in wheels-out) was 149.43 ± 50.82 (SD) minutes. One patient (2.7%) developed a fracture-related infection (FRI), two patients (5.4%) had wound complications, and one patient (2.7%) developed a deep vein thrombosis (DVT) following surgery. All fractures healed by 6 months, and no patient underwent removal of symptomatic hardware. Three patients underwent secondary operation; one patient had repeated irrigation and debridement of a confirmed FRI, one manipulation under anesthesia for knee contracture, and one revision ORIF after loss of distal fixation. Patients displayed a mean knee ROM of 106.53 ± 21.64 degrees (SD) and 118.51 ± 16.87 degrees (SD) at the 3- and 6-month points, respectively. The novel locking "star" patella plate appears to be a reliable and safe method of treatment for the most complex patella fractures.

Authors

Institutions

Publication Details

Journal
The Journal of Knee Surgery
Published
2026-05-11
DOI
https://doi.org/10.1055/a-2865-2853
Primary Topic
Lower Extremity Biomechanics and Pathologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Outcomes of Variable-Angle Locking Anterior Patella Plating for the Treatment of OTA 34-C3 Patella Fractures

Alexander M. Lashgari, Steven Rivero, Kenneth A. Egol, Sanjit R. Konda et al.
The Journal of Knee Surgery
Lower Extremity Biomechanics and Pathologies
article

Outcomes of Variable-Angle Locking Anterior Patella Plating for the Treatment of OTA 34-C3 Patella Fractures

Alexander M. Lashgari, Steven Rivero, Kenneth A. Egol, Sanjit R. Konda, Abhishek Ganta
article en

Abstract

Abstract: ) treated at one multisite, urban, academic institution were identified. All fractures were classified as OTA 34-C3. The mean operating room time (wheels-in wheels-out) was 149.43 ± 50.82 (SD) minutes. One patient (2.7%) developed a fracture-related infection (FRI), two patients (5.4%) had wound complications, and one patient (2.7%) developed a deep vein thrombosis (DVT) following surgery. All fractures healed by 6 months, and no patient underwent removal of symptomatic hardware. Three patients underwent secondary operation; one patient had repeated irrigation and debridement of a confirmed FRI, one manipulation under anesthesia for knee contracture, and one revision ORIF after loss of distal fixation. Patients displayed a mean knee ROM of 106.53 ± 21.64 degrees (SD) and 118.51 ± 16.87 degrees (SD) at the 3- and 6-month points, respectively. The novel locking "star" patella plate appears to be a reliable and safe method of treatment for the most complex patella fractures.

The Journal of Knee Surgery
NYU Langone Health (US), Jamaica Hospital (US), New York University Langone Orthopedic Hospital (US)
Sustainable cities and communities
Openalex Percentile: Top 9%
Lower Extremity Biomechanics and Pathologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Outcomes of Variable-Angle Locking Anterior Patella Plating for the Treatment of OTA 34-C3 Patella Fractures — Alexander M. Lashgari, Steven Rivero, et al. · The Journal of Knee Surgery (2026) | TGRS Research Map | TGRS