Estimating Implantable Collamer Lens Vault From Scheimpflug-Derived Postoperative Anterior Chamber Volume Change in Chinese Eyes

Purpose: To compensate for Pentacam's (Oculus Optikgeräte GmbH) flaw in Implantable Collamer Lens (ICL; STAAR Surgical) vault assessment, which is the difficulty to clearly detect the ICL itself, for the improvement of Pentacam's performance in the follow-up after ICL implantation. Methods: One hundred fourteen eyes that had ICL implantation at Beijing Fenglian Eyecare Beau Care Clinic were pre-screened from January to December 2024 and were randomly divided into the formula establishment group (76 eyes) and the formula validation group (38 eyes). A regression formula was worked out with the perioperative variables measured by Pentacam to best correlate with postoperative ICL vault measured by anterior segment optical coherence tomography (AS-OCT) using Pearson correlations and multiple linear regressions in the formula establishment group, and it was then tested in the validation group. Results: ICL vault showed significant positive linear correlations with anterior chamber volume change (ΔACV) ( r = 0.845, P < .001), anterior chamber depth ( r = 0.441, P < .001), and white-to-white distance ( r = 0.342, P < .01). However, there was no linear correlation between ICL vault and ICL size/direction/anterior chamber angle ( P > .05). The estimation formula was: ICL vault (μm) = 1,710.94 – 157.81 × ICL size (mm) +13.20 × ΔACV (μL). The validation results showed that the mean absolute error, median absolute error, and root mean square error were 82.27, 77.54, and 99.31 μm, respectively. Conclusions: This study established the ICL vault estimation formula based on ΔACV measured by Pentacam to best correlate with vault measured by AS-OCT. It compensates for Pentacam's flaw in ICL vault assessment, which is the difficulty to clearly detect the ICL itself, and is especially valuable when AS-OCT is unavailable.

Authors

Institutions

Publication Details

Journal
Journal of Refractive Surgery
Published
2026-05-01
DOI
https://doi.org/10.3928/1081597x-20260223-01
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Estimating Implantable Collamer Lens Vault From Scheimpflug-Derived Postoperative Anterior Chamber Volume Change in Chinese Eyes

Junquan Zan, Meng Yang, Xiaoyong Chen, Yinan Liu
Journal of Refractive Surgery
Corneal surgery and disorders
article

Estimating Implantable Collamer Lens Vault From Scheimpflug-Derived Postoperative Anterior Chamber Volume Change in Chinese Eyes

Junquan Zan, Meng Yang, Xiaoyong Chen, Yinan Liu
article en

Abstract

Purpose: To compensate for Pentacam's (Oculus Optikgeräte GmbH) flaw in Implantable Collamer Lens (ICL; STAAR Surgical) vault assessment, which is the difficulty to clearly detect the ICL itself, for the improvement of Pentacam's performance in the follow-up after ICL implantation. Methods: One hundred fourteen eyes that had ICL implantation at Beijing Fenglian Eyecare Beau Care Clinic were pre-screened from January to December 2024 and were randomly divided into the formula establishment group (76 eyes) and the formula validation group (38 eyes). A regression formula was worked out with the perioperative variables measured by Pentacam to best correlate with postoperative ICL vault measured by anterior segment optical coherence tomography (AS-OCT) using Pearson correlations and multiple linear regressions in the formula establishment group, and it was then tested in the validation group. Results: ICL vault showed significant positive linear correlations with anterior chamber volume change (ΔACV) ( r = 0.845, P < .001), anterior chamber depth ( r = 0.441, P < .001), and white-to-white distance ( r = 0.342, P < .01). However, there was no linear correlation between ICL vault and ICL size/direction/anterior chamber angle ( P > .05). The estimation formula was: ICL vault (μm) = 1,710.94 – 157.81 × ICL size (mm) +13.20 × ΔACV (μL). The validation results showed that the mean absolute error, median absolute error, and root mean square error were 82.27, 77.54, and 99.31 μm, respectively. Conclusions: This study established the ICL vault estimation formula based on ΔACV measured by Pentacam to best correlate with vault measured by AS-OCT. It compensates for Pentacam's flaw in ICL vault assessment, which is the difficulty to clearly detect the ICL itself, and is especially valuable when AS-OCT is unavailable.

Journal of Refractive SurgeryVol. 42(5)
Peking University (CN), Associated Eyecare (US), Peking University Third Hospital (CN)
Openalex Percentile: Top 4%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.