Avoidance of disruptions on KSTAR due to vertical displacement events via novel real-time stability assessment

Disruption avoidance via the DECAF approach has been achieved on KSTAR using a novel real-time vertical stability assessment and a multiactuator feedback control strategy. The development of disruption avoidance strategies with reactor-relevant reliability is an urgent activity, enabling future fusion power plants. The stability metric employed is based on a new formulation of a vertical force gradient balance metric evaluated across the poloidal cross section of the plasma, with parameters tuned using historical data. Evaluation of this metric on a validation set of 400 recent KSTAR shots indicates >82% of Vertical displacement events can be avoided via feedback control. Essential to its calculation is the two-dimensional toroidal current density distribution in the plasma. Measurement of this profile faster than fully-converged equilibrium reconstructions can deliver is found to improve forecaster performance and is achieved with a surrogate model that takes as input magnetic diagnostic measurements and outputs the current profile on a basis comprising the top principal components of historical current profiles (from past equilibrium reconstructions). This method solves the non-uniqueness problem typically faced when reconstructing current profiles directly from diagnostics, while improving computational time and accuracy. On average, profiles produced by this model reach coefficients of determination of >0.99 with respect to those from equilibrium reconstructions. The avoidance actuators employed include poloidal field coils and an electron cyclotron current drive system. The multiactuator approach, as shown in this first demonstration, allows disruption avoidance while minimizing impact to operational performance. This ability, along with its flexibility and speed, makes this new approach an attractive option for avoiding these types of disruptions in reactors.

Authors

Institutions

Publication Details

Journal
Physics of Plasmas
Published
2026-05-01
DOI
https://doi.org/10.1063/5.0320639
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Avoidance of disruptions on KSTAR due to vertical displacement events via novel real-time stability assessment

Y M Park, F. Sheehan, J. R. Jepson, M.H. Woo et al.
Physics of Plasmas
Magnetic confinement fusion research
article

Avoidance of disruptions on KSTAR due to vertical displacement events via novel real-time stability assessment

Y M Park, F. Sheehan, J. R. Jepson, M.H. Woo, J. Riquezes, M. Tobin, K. Erickson, V. Zamkovska, J. Barr, G. Bustos-Ramirez, G. Tillinghast, S. A. Sabbagh, Y. Lee, R. Shousha, H. K. Lee
article en

Abstract

Disruption avoidance via the DECAF approach has been achieved on KSTAR using a novel real-time vertical stability assessment and a multiactuator feedback control strategy. The development of disruption avoidance strategies with reactor-relevant reliability is an urgent activity, enabling future fusion power plants. The stability metric employed is based on a new formulation of a vertical force gradient balance metric evaluated across the poloidal cross section of the plasma, with parameters tuned using historical data. Evaluation of this metric on a validation set of 400 recent KSTAR shots indicates >82% of Vertical displacement events can be avoided via feedback control. Essential to its calculation is the two-dimensional toroidal current density distribution in the plasma. Measurement of this profile faster than fully-converged equilibrium reconstructions can deliver is found to improve forecaster performance and is achieved with a surrogate model that takes as input magnetic diagnostic measurements and outputs the current profile on a basis comprising the top principal components of historical current profiles (from past equilibrium reconstructions). This method solves the non-uniqueness problem typically faced when reconstructing current profiles directly from diagnostics, while improving computational time and accuracy. On average, profiles produced by this model reach coefficients of determination of >0.99 with respect to those from equilibrium reconstructions. The avoidance actuators employed include poloidal field coils and an electron cyclotron current drive system. The multiactuator approach, as shown in this first demonstration, allows disruption avoidance while minimizing impact to operational performance. This ability, along with its flexibility and speed, makes this new approach an attractive option for avoiding these types of disruptions in reactors.

Physics of PlasmasVol. 33(5)
City University of New York (US), Princeton Plasma Physics Laboratory (US), Korea Institute of Fusion Energy (KR), General Atomics (United States) (US), Columbia University (US)
Affordable and clean energy
Openalex Percentile: Top 4%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.