Impact of CT Acquisition Parameters on Deep Learning of Aortic Segmentation Performance: Systematic Review

Automatic segmentation of computed tomography (CT) images is fundamental for quantitative anatomical analysis in a wide range of clinical applications. Despite remarkable advances in artificial intelligence (AI), CT acquisition parameters critically affect image quality, structural fidelity, and model performance. This narrative review investigates how variations in CT acquisition influence image quality and accuracy of AI-based aortic segmentation models. Following PRISMA guidelines, a narrative review was conducted to identify studies assessing how CT technical parameters influence image quality and AI-based aortic segmentation accuracy. From 376 initial records, 13 studies met the inclusion criteria. Thinner slices improved segmentation accuracy, increasing the Dice Similarity Coefficient (DSC) from 0.75 to 0.87 and reducing the 95th Percentile Hausdorff Distance from 2.1 to 1.2 mm. Larger slice spacing (3 mm) worsened accuracy by about 12%, while 1 mm slices reduced aortic diameter errors to below 2%. Faster acquisitions decreased image noise from 32.3 ± 6.3 to 22.1 ± 5.9 HU. Among segmentation models, 2D-3D U-Net ensembles achieved the highest accuracy (DSC = 0.928 ± 0.026), with thrombus segmentation (DSC = 0.782 ± 0.170) outperforming vessel segmentation (DSC = 0.481 ± 0.155). Optimal pixel spacing (0.665 × 0.665 mm) improved image fidelity, yielding a PSNR of 16.28 dB and lower MSE (2729.67). CT acquisition parameters critically impact the reliability of AI-driven aortic segmentation. Optimizing these parameters improves model performance, but the opacity of AI systems still limits clinical interpretability, highlighting the need for standardized acquisition protocols and explainable AI approaches.

Authors

Institutions

Publication Details

Journal
Journal of Imaging Informatics in Medicine
Published
2026-05-11
DOI
https://doi.org/10.1007/s10278-026-01963-7
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of CT Acquisition Parameters on Deep Learning of Aortic Segmentation Performance: Systematic Review

Bianca Pane, Alice Fantazzini, Giovanni Pratesi, Curzio Basso et al.
Journal of Imaging Informatics in Medicine
Advanced X-ray and CT Imaging
article

Impact of CT Acquisition Parameters on Deep Learning of Aortic Segmentation Performance: Systematic Review

Bianca Pane, Alice Fantazzini, Giovanni Pratesi, Curzio Basso, Giovanni Spinella, Michele Conti, Marco Magliocco, Erika Spinella
article en

Abstract

Automatic segmentation of computed tomography (CT) images is fundamental for quantitative anatomical analysis in a wide range of clinical applications. Despite remarkable advances in artificial intelligence (AI), CT acquisition parameters critically affect image quality, structural fidelity, and model performance. This narrative review investigates how variations in CT acquisition influence image quality and accuracy of AI-based aortic segmentation models. Following PRISMA guidelines, a narrative review was conducted to identify studies assessing how CT technical parameters influence image quality and AI-based aortic segmentation accuracy. From 376 initial records, 13 studies met the inclusion criteria. Thinner slices improved segmentation accuracy, increasing the Dice Similarity Coefficient (DSC) from 0.75 to 0.87 and reducing the 95th Percentile Hausdorff Distance from 2.1 to 1.2 mm. Larger slice spacing (3 mm) worsened accuracy by about 12%, while 1 mm slices reduced aortic diameter errors to below 2%. Faster acquisitions decreased image noise from 32.3 ± 6.3 to 22.1 ± 5.9 HU. Among segmentation models, 2D-3D U-Net ensembles achieved the highest accuracy (DSC = 0.928 ± 0.026), with thrombus segmentation (DSC = 0.782 ± 0.170) outperforming vessel segmentation (DSC = 0.481 ± 0.155). Optimal pixel spacing (0.665 × 0.665 mm) improved image fidelity, yielding a PSNR of 16.28 dB and lower MSE (2729.67). CT acquisition parameters critically impact the reliability of AI-driven aortic segmentation. Optimizing these parameters improves model performance, but the opacity of AI systems still limits clinical interpretability, highlighting the need for standardized acquisition protocols and explainable AI approaches.

Journal of Imaging Informatics in Medicine
University of Pavia (IT), IRCCS Policlinico San Donato (IT), Ospedale Policlinico San Martino (IT), Camelot Biomedical Systems (Italy) (IT), University of Genoa (IT)
European Commission, Università degli Studi di Genova, HORIZON EUROPE Reforming and enhancing the European Research and Innovation system
Reduced inequalities
Openalex Percentile: Top 9%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.