In Vitro Study of Nebulizer Position Effects on Colistimethate Sodium Administration, Drug Deposition, and Filter Pressure Drop in Mechanical Ventilation

BACKGROUND: Colistimethate sodium (CMS) is increasingly being administered as aerosol therapy in mechanically ventilated patients. Although vibrating-mesh nebulizers (VMNs) are commonly used, the impact of repeated high-dose CMS administration on expiratory filter loading and circuit pressure drop has not been well defined. This study evaluated circuit deposition patterns and changes in expiratory filter pressure drop according to the nebulizer position. METHODS: 5). Drug deposition was quantified by high-performance liquid chromatography. Pressure drop, defined as the difference between upstream and downstream pressure across the expiratory high-efficiency particulate air filter, was measured over repeated administrations and analyzed using a mixed repeated-measures model. RESULTS: = .01), with higher pressure drop after 14 treatments. In contrast, humidifier-inlet placement was associated with greater drug accumulation within the humidifier chamber (35.59 ± 6.21%) and a smaller increase in pressure drop. CONCLUSIONS: During repeated high-dose CMS administration, the nebulizer position influenced circuit deposition patterns and expiratory filter pressure drop. Placement at the Y-adapter was associated with greater expiratory limb deposition and increased filter pressure drop over time, whereas humidifier-inlet placement shifted the drug accumulation proximally within the circuit.

Authors

Institutions

Publication Details

Journal
Respiratory Care
Published
2026-05-11
DOI
https://doi.org/10.1177/19433654261445030
Primary Topic
Inhalation and Respiratory Drug Delivery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Vitro Study of Nebulizer Position Effects on Colistimethate Sodium Administration, Drug Deposition, and Filter Pressure Drop in Mechanical Ventilation

Yin-Chi Wu, Meng‐Jer Hsieh, Wei-Ren Ke, Ming‐Hui Chen et al.
Respiratory Care
Inhalation and Respiratory Drug Delivery
article

In Vitro Study of Nebulizer Position Effects on Colistimethate Sodium Administration, Drug Deposition, and Filter Pressure Drop in Mechanical Ventilation

Yin-Chi Wu, Meng‐Jer Hsieh, Wei-Ren Ke, Ming‐Hui Chen, Meng‐Fang Wu, Hui-Ling Lin
article en

Abstract

BACKGROUND: Colistimethate sodium (CMS) is increasingly being administered as aerosol therapy in mechanically ventilated patients. Although vibrating-mesh nebulizers (VMNs) are commonly used, the impact of repeated high-dose CMS administration on expiratory filter loading and circuit pressure drop has not been well defined. This study evaluated circuit deposition patterns and changes in expiratory filter pressure drop according to the nebulizer position. METHODS: 5). Drug deposition was quantified by high-performance liquid chromatography. Pressure drop, defined as the difference between upstream and downstream pressure across the expiratory high-efficiency particulate air filter, was measured over repeated administrations and analyzed using a mixed repeated-measures model. RESULTS: = .01), with higher pressure drop after 14 treatments. In contrast, humidifier-inlet placement was associated with greater drug accumulation within the humidifier chamber (35.59 ± 6.21%) and a smaller increase in pressure drop. CONCLUSIONS: During repeated high-dose CMS administration, the nebulizer position influenced circuit deposition patterns and expiratory filter pressure drop. Placement at the Y-adapter was associated with greater expiratory limb deposition and increased filter pressure drop over time, whereas humidifier-inlet placement shifted the drug accumulation proximally within the circuit.

Respiratory Care
Chang Gung University of Science and Technology (TW), National Taiwan University (TW), Chang Gung University (TW), Chang Gung Memorial Hospital (TW), Linkou Chang Gung Memorial Hospital (TW)
Good health and well-being
Openalex Percentile: Top 6%
Inhalation and Respiratory Drug Delivery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.