Thermal Buckling Behaviors of a Fixed-Roof Steel Tank Subjected to Two Adjacent Pool Fires

In a tank farm, even if the separation distance meets the codes and standards, a pool fire in one tank may spread quickly to another tank. Most destructive and uncontrollable fire accidents are induced with multiple pool fires. In current work, the thermal buckling behaviors of a fixed-roof tank subjected to one (two) neighboring pool fire(s) (burning tanks) are numerically studied. The effects of the number of the pool fires, the separation distance between two pool fires, and the distance between the adjacent tank and pool fires are analyzed. The results indicate that the thermal buckling zone of the target tank subjected to two pool fires is larger than that subjected to one pool fire, and the maximum displacement for two pool fires is almost equal to that for one pool fire. The target tank subjected to one pool fire loses stability and reaches a new stable state faster than that subjected to two pool fires. The thermal buckling zone expands as the distance between the two pool fires increases but decreases with increasing separation distance between the pool fire and the target tank. The findings provide useful guidance for the structural optimization of steel storage tanks against pool fire exposure and offer theoretical support for emergency response and fire rescue in tank farms.

Authors

Institutions

Publication Details

Journal
Fire
Published
2026-05-11
DOI
https://doi.org/10.3390/fire9050198
Primary Topic
Risk and Safety Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal Buckling Behaviors of a Fixed-Roof Steel Tank Subjected to Two Adjacent Pool Fires

Yunhao Li, Song Lin
Fire
Risk and Safety Analysis
article

Thermal Buckling Behaviors of a Fixed-Roof Steel Tank Subjected to Two Adjacent Pool Fires

Yunhao Li, Song Lin
article en

Abstract

In a tank farm, even if the separation distance meets the codes and standards, a pool fire in one tank may spread quickly to another tank. Most destructive and uncontrollable fire accidents are induced with multiple pool fires. In current work, the thermal buckling behaviors of a fixed-roof tank subjected to one (two) neighboring pool fire(s) (burning tanks) are numerically studied. The effects of the number of the pool fires, the separation distance between two pool fires, and the distance between the adjacent tank and pool fires are analyzed. The results indicate that the thermal buckling zone of the target tank subjected to two pool fires is larger than that subjected to one pool fire, and the maximum displacement for two pool fires is almost equal to that for one pool fire. The target tank subjected to one pool fire loses stability and reaches a new stable state faster than that subjected to two pool fires. The thermal buckling zone expands as the distance between the two pool fires increases but decreases with increasing separation distance between the pool fire and the target tank. The findings provide useful guidance for the structural optimization of steel storage tanks against pool fire exposure and offer theoretical support for emergency response and fire rescue in tank farms.

FireVol. 9(5)
Changzhou University (CN)
Sustainable cities and communities
Openalex Percentile: Top 6%
Risk and Safety Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.