Differences in Cyclotorsion Compensation Between Low, Medium, and Large Angles in Myopic PRK: Visual and Refractive Results

Purpose: To evaluate the differences in myopic photorefractive keratectomy (PRK) outcomes between small, medium, and large cyclorotational angle degrees. Methods: This retrospective comparative study was conducted at Care Vision Laser Center, Tel Aviv, Israel. The study included consecutive patients who underwent myopic PRK between 2012 and 2023. Patients were divided into three groups according to their cyclorotation angle magnitude. A comparison of baseline and intraoperative parameters was performed. Refractive and visual outcomes were assessed and an Alpins vector analysis was performed. Multiple linear regression was performed to identify the effect of potential confounders. Results: A total of 17,214 eyes from 10,859 patients were analyzed (mean age: 25.9 ± 7.5 years, 55.7% male and 44.3% female). The large cyclorotation angle group exhibited statistically but not clinically significant lower corrected (CDVA) and uncorrected (UDVA) distance visual acuity at final follow-up compared to the other groups. However, no significant differences were observed in refractive outcomes, safety and efficacy indexes, or Alpins vector analysis. On regression analysis, preoperative CDVA was the only significant predictor of final CDVA (β = 0.633, P < .01). Although cylinder magnitude did not vary between the groups at baseline, in subgroup analysis by stratification into higher cylinders, efficacy was significantly lower in the small compared to the medium cyclorotation group, but the result was clinically negligible. Conclusions: Cyclorotation angles up to 10 degrees had no clinically significant impact on PRK refractive outcomes. These findings suggest that modern excimer laser systems effectively compensate for cyclorotation within this range, ensuring precise treatment delivery.

Authors

Institutions

Publication Details

Journal
Journal of Refractive Surgery
Published
2026-05-01
DOI
https://doi.org/10.3928/1081597x-20260218-02
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Differences in Cyclotorsion Compensation Between Low, Medium, and Large Angles in Myopic PRK: Visual and Refractive Results

Dror Ben Ephraim Noyman, Tzahi Sela, Waseem Nasser, Gur Munzer et al.
Journal of Refractive Surgery
Corneal surgery and disorders
article

Differences in Cyclotorsion Compensation Between Low, Medium, and Large Angles in Myopic PRK: Visual and Refractive Results

Dror Ben Ephraim Noyman, Tzahi Sela, Waseem Nasser, Gur Munzer, Margarita Safir, Adir Sommer, Michael Mimouni, Igor Kaiserman
article en

Abstract

Purpose: To evaluate the differences in myopic photorefractive keratectomy (PRK) outcomes between small, medium, and large cyclorotational angle degrees. Methods: This retrospective comparative study was conducted at Care Vision Laser Center, Tel Aviv, Israel. The study included consecutive patients who underwent myopic PRK between 2012 and 2023. Patients were divided into three groups according to their cyclorotation angle magnitude. A comparison of baseline and intraoperative parameters was performed. Refractive and visual outcomes were assessed and an Alpins vector analysis was performed. Multiple linear regression was performed to identify the effect of potential confounders. Results: A total of 17,214 eyes from 10,859 patients were analyzed (mean age: 25.9 ± 7.5 years, 55.7% male and 44.3% female). The large cyclorotation angle group exhibited statistically but not clinically significant lower corrected (CDVA) and uncorrected (UDVA) distance visual acuity at final follow-up compared to the other groups. However, no significant differences were observed in refractive outcomes, safety and efficacy indexes, or Alpins vector analysis. On regression analysis, preoperative CDVA was the only significant predictor of final CDVA (β = 0.633, P < .01). Although cylinder magnitude did not vary between the groups at baseline, in subgroup analysis by stratification into higher cylinders, efficacy was significantly lower in the small compared to the medium cyclorotation group, but the result was clinically negligible. Conclusions: Cyclorotation angles up to 10 degrees had no clinically significant impact on PRK refractive outcomes. These findings suggest that modern excimer laser systems effectively compensate for cyclorotation within this range, ensuring precise treatment delivery.

Journal of Refractive SurgeryVol. 42(5)
Ben-Gurion University of the Negev (IL), Tel Aviv University (IL), Rabin Medical Center (IL), Rambam Health Care Campus (IL), Barzilai Medical Center (IL), Rappaport Family Institute for Research in the Medical Sciences (IL), Notal Vision (Israel) (IL)
Openalex Percentile: Top 4%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.