Adsorptive Treatment of Cr (VI)-Contaminated Wastewater in a Fixed-Bed Column Using Hydrothermal Chitosan/Polyvinyl Alcohol Beads and Life Cycle Assessment

Hydrothermally treated chitosan/polyvinyl alcohol beads (H-CS/PVA) were used as filler material in a fixed-bed column for continuous Cr (VI) removal. The effects of main operational parameters, namely bed height, initial concentration and flow rate, were evaluated in the respective ranges of 2–6 cm, 20–60 mg/L and 2.5–7.5 mL/min. Maximum removal efficiency and adsorption capacity were calculated as 64.2% and 15.53 mg/g, respectively. The corresponding breakthrough curves were analyzed by Yoon–Nelson, Adams–Bohart, Thomas and BDST (Bed Depth–Service Time) models, out of which the highest consistency was achieved with the Yoon–Nelson model for all studied conditions. The adsorbent maintained strong reusability, showing minimal loss (~2.5%) in desorption efficiency across three successive regeneration cycles with 0.1 M NaOH as the eluent. SEM and SEM–EDX analyses confirmed the presence of chromium on the H-CS/PVA surface at an elemental fraction of 1.03% (w.). Furthermore, FTIR and XPS analyses verified the role of amine and hydroxyl functionalities in the complexation and adsorption of Cr (VI). Overall, a column system operated under optimal conditions (Hbed: 6 cm, C0: 40 mg/L, and column diameter: 2.5 cm) and regenerated three times can efficiently treat 20 L of Cr (VI)-contaminated wastewater, resulting in an associated environmental impact of 0.896 kg CO2-eq.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2026-05-09
DOI
https://doi.org/10.3390/polym18101167
Primary Topic
Adsorption and biosorption for pollutant removal
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adsorptive Treatment of Cr (VI)-Contaminated Wastewater in a Fixed-Bed Column Using Hydrothermal Chitosan/Polyvinyl Alcohol Beads and Life Cycle Assessment

Yaşar Aydin, Eylül Kösoğlu, Asude Demirci Ulke
Polymers
Adsorption and biosorption for pollutant removal
article

Adsorptive Treatment of Cr (VI)-Contaminated Wastewater in a Fixed-Bed Column Using Hydrothermal Chitosan/Polyvinyl Alcohol Beads and Life Cycle Assessment

Yaşar Aydin, Eylül Kösoğlu, Asude Demirci Ulke
article en

Abstract

Hydrothermally treated chitosan/polyvinyl alcohol beads (H-CS/PVA) were used as filler material in a fixed-bed column for continuous Cr (VI) removal. The effects of main operational parameters, namely bed height, initial concentration and flow rate, were evaluated in the respective ranges of 2–6 cm, 20–60 mg/L and 2.5–7.5 mL/min. Maximum removal efficiency and adsorption capacity were calculated as 64.2% and 15.53 mg/g, respectively. The corresponding breakthrough curves were analyzed by Yoon–Nelson, Adams–Bohart, Thomas and BDST (Bed Depth–Service Time) models, out of which the highest consistency was achieved with the Yoon–Nelson model for all studied conditions. The adsorbent maintained strong reusability, showing minimal loss (~2.5%) in desorption efficiency across three successive regeneration cycles with 0.1 M NaOH as the eluent. SEM and SEM–EDX analyses confirmed the presence of chromium on the H-CS/PVA surface at an elemental fraction of 1.03% (w.). Furthermore, FTIR and XPS analyses verified the role of amine and hydroxyl functionalities in the complexation and adsorption of Cr (VI). Overall, a column system operated under optimal conditions (Hbed: 6 cm, C0: 40 mg/L, and column diameter: 2.5 cm) and regenerated three times can efficiently treat 20 L of Cr (VI)-contaminated wastewater, resulting in an associated environmental impact of 0.896 kg CO2-eq.

PolymersVol. 18(10)
Maltepe University (TR), Marmara University (TR)
Clean water and sanitation
Openalex Percentile: Top 8%
Adsorption and biosorption for pollutant removal
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Adsorptive Treatment of Cr (VI)-Contaminated Wastewater in a Fixed-Bed Column Using Hydrothermal Chitosan/Polyvinyl Alcohol Beads and Life Cycle Assessment — Yaşar Aydin, Eylül Kösoğlu, et al. · Polymers (2026) | TGRS Research Map | TGRS