Obturator Dislocations Following Direct Anterior Approach Total Hip Arthroplasty: Two Case Reports With Analysis of Implant and Spinopelvic Factors

ABSTRACT Dislocation remains a potential complication after total hip arthroplasty (THA), even with the anterior approach, which is generally associated with lower instability rates. Obturator dislocation, although well‐documented in native hips following high‐energy trauma, is extremely rare in the context of THA and has not been previously described in patients with preoperative spinopelvic assessment. We report two cases of obturator dislocation following direct anterior approach THA in young female patients without medical comorbidities. Both dislocations occurred during extreme hip flexion combined with abduction and external rotation. In one case, closed reduction attempts initially failed, requiring reduction on a traction table. Radiographic and 3D analyses revealed shared features, including significant medialization of the acetabular component (10 mm), low combined anteversion (16° and 24°), and lumbopelvic mobility patterns dominated by hip flexion. Preoperative functional imaging showed no signs of spinopelvic imbalance or stiffness. Both patients exhibited a “hip user” profile with low pelvic incidence and distal lumbar lordosis apex. These cases highlight multiple converging factors contributing to instability: loss of offset due to cup medialization, stem retroversion resulting in low combined anteversion, and postoperative increase in compensatory hip flexion. Notably, no classic spinopelvic risk factors were present. These findings underscore the need for precise implant positioning, especially for acetabular positioning and femoral version.

Authors

Institutions

Publication Details

Journal
Clinical Case Reports
Published
2026-05-01
DOI
https://doi.org/10.1002/ccr3.72694
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Obturator Dislocations Following Direct Anterior Approach Total Hip Arthroplasty: Two Case Reports With Analysis of Implant and Spinopelvic Factors

Florence Aïm, Guillaume Auberger, Thomas Aubert, Alois Bouy et al.
Clinical Case Reports
Orthopaedic implants and arthroplasty
article

Obturator Dislocations Following Direct Anterior Approach Total Hip Arthroplasty: Two Case Reports With Analysis of Implant and Spinopelvic Factors

Florence Aïm, Guillaume Auberger, Thomas Aubert, Alois Bouy, Briac Peynet
article en

Abstract

ABSTRACT Dislocation remains a potential complication after total hip arthroplasty (THA), even with the anterior approach, which is generally associated with lower instability rates. Obturator dislocation, although well‐documented in native hips following high‐energy trauma, is extremely rare in the context of THA and has not been previously described in patients with preoperative spinopelvic assessment. We report two cases of obturator dislocation following direct anterior approach THA in young female patients without medical comorbidities. Both dislocations occurred during extreme hip flexion combined with abduction and external rotation. In one case, closed reduction attempts initially failed, requiring reduction on a traction table. Radiographic and 3D analyses revealed shared features, including significant medialization of the acetabular component (10 mm), low combined anteversion (16° and 24°), and lumbopelvic mobility patterns dominated by hip flexion. Preoperative functional imaging showed no signs of spinopelvic imbalance or stiffness. Both patients exhibited a “hip user” profile with low pelvic incidence and distal lumbar lordosis apex. These cases highlight multiple converging factors contributing to instability: loss of offset due to cup medialization, stem retroversion resulting in low combined anteversion, and postoperative increase in compensatory hip flexion. Notably, no classic spinopelvic risk factors were present. These findings underscore the need for precise implant positioning, especially for acetabular positioning and femoral version.

Clinical Case ReportsVol. 14(5)
Groupe Hospitalier Diaconesses Croix Saint-Simon (FR)
Openalex Percentile: Top 4%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Obturator Dislocations Following Direct Anterior Approach Total Hip Arthroplasty: Two Case Reports With Analysis of Implant and Spinopelvic Factors — Florence Aïm, Guillaume Auberger, et al. · Clinical Case Reports (2026) | TGRS Research Map | TGRS