Comparison of decentration, tilt, and dynamic stability between retropupillary iris claw and scleral fixated intraocular lenses with flanged haptics

PURPOSE: To compare decentration, tilt, and dynamic stability ("wobble") between retropupillary fixated iris claw intraocular lenses (IOL) and double needle flanged scleral fixated technique. SETTING: Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria. DESIGN: Monocentric comparative observational study. METHODS: Secondary intraocular lens alignment was evaluated using swept source anterior segment optical coherence tomography to quantify decentration and tilt. Dynamic lens behavior was assessed using a Purkinje meter during 9° saccadic eye movements. Additional outcomes included visual acuity, refraction, and complications. RESULTS: Seventy-two eyes of 72 patients were included, comprising 31 eyes with retropupillary iris claw intraocular lenses and 41 eyes with scleral fixated intraocular lenses. Mean decentration was similar between groups, with no statistically significant difference (598 ± 303 µm vs 535 ± 261 µm; p = 0.57). Mean tilt was lower in the iris claw group than in the scleral fixated group, with a statistically significant difference between groups (6.52 ± 3.20° vs 8.93 ± 5.02°; p = 0.03). Across all gaze directions, iris claw lenses demonstrated greater dynamic instability, with larger post saccadic oscillation amplitudes, longer stationary times, and lower damping ratios (all p < 0.001). Visual acuity, refraction, and complication rates were comparable between groups. The intraocular lens iris distance was smaller in the iris claw group. CONCLUSIONS: Decentration was comparable, whereas iris claw lenses showed less tilt but greater dynamic instability than scleral fixated lenses.

Authors

Institutions

Publication Details

Journal
Journal of Cataract & Refractive Surgery
Published
2026-05-11
DOI
https://doi.org/10.1097/j.jcrs.0000000000001975
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of decentration, tilt, and dynamic stability between retropupillary iris claw and scleral fixated intraocular lenses with flanged haptics

Martin Kronschläger, Juan Tabernero, Johannes Zeilinger, Sophie Maedel et al.
Journal of Cataract & Refractive Surgery
Intraocular Surgery and Lenses
article

Comparison of decentration, tilt, and dynamic stability between retropupillary iris claw and scleral fixated intraocular lenses with flanged haptics

Martin Kronschläger, Juan Tabernero, Johannes Zeilinger, Sophie Maedel, Paul Regitnig, Manuel Ruiss, Pablo Artal, Oliver Findl
article en

Abstract

PURPOSE: To compare decentration, tilt, and dynamic stability ("wobble") between retropupillary fixated iris claw intraocular lenses (IOL) and double needle flanged scleral fixated technique. SETTING: Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria. DESIGN: Monocentric comparative observational study. METHODS: Secondary intraocular lens alignment was evaluated using swept source anterior segment optical coherence tomography to quantify decentration and tilt. Dynamic lens behavior was assessed using a Purkinje meter during 9° saccadic eye movements. Additional outcomes included visual acuity, refraction, and complications. RESULTS: Seventy-two eyes of 72 patients were included, comprising 31 eyes with retropupillary iris claw intraocular lenses and 41 eyes with scleral fixated intraocular lenses. Mean decentration was similar between groups, with no statistically significant difference (598 ± 303 µm vs 535 ± 261 µm; p = 0.57). Mean tilt was lower in the iris claw group than in the scleral fixated group, with a statistically significant difference between groups (6.52 ± 3.20° vs 8.93 ± 5.02°; p = 0.03). Across all gaze directions, iris claw lenses demonstrated greater dynamic instability, with larger post saccadic oscillation amplitudes, longer stationary times, and lower damping ratios (all p < 0.001). Visual acuity, refraction, and complication rates were comparable between groups. The intraocular lens iris distance was smaller in the iris claw group. CONCLUSIONS: Decentration was comparable, whereas iris claw lenses showed less tilt but greater dynamic instability than scleral fixated lenses.

Journal of Cataract & Refractive Surgery
Sigmund Freud Privatuniversität Wien (AT), Vienna Institute for Research in Ocular Surgery (AT), Universidad de Murcia (ES)
Openalex Percentile: Top 5%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.