Mortality in patients with cardiogenic shock associated with the use of microaxial flow pump: a systematic review and meta-analysis

In this article we aim to evaluate the impact of the microaxial flow pump on mortality in patients with cardiogenic shock associated with acute myocardial infarction through a systematic review and meta-analysis of clinical trials and cohort studies.Patients with acute myocardial infarction, both with and without ST-segment elevation, associated with cardiogenic shock and treated with a microaxial flow pump, were included.Mortality data and implantation time of the device were reported.Patients with more than 24 hours of shock progression, those with other shock etiologies, patients with mechanical complications from acute myocardial infarction, and other comorbidity, were excluded.The search was conducted in PubMed and Web of Science databases for articles published from 2019 until November 10, 2024.Risk of bias was evaluated using the RoB 2 tool and the ROBINS-E, while statistical analysis was performed using Review Manager 5.4.1 software.A total of 1,000 patients from five studies were included.The use of the microaxial flow pump was associated with a reduction in mortality compared to placebo (OR: 0.6; 95% CI: 0.42-0.85;p = 0.005).However, there were no significant differences in mortality related to the timing of the microaxial flow pump implantation (before, during, or after percutaneous coronary intervention) (OR: 0.85; 95% CI: 0.59-1.22;p = 0.37).Patients with cardiogenic shock have gained access to various treatment opportunities that were not available until recently.The results suggest that the microaxial flow pump is a therapeutic option in these patients with significant effects on mortality.

Authors

Publication Details

Journal
Archivos de cardiolog�a de M�xico (English ed Internet)
Published
2026-05-11
DOI
https://doi.org/10.24875/acme.m26000648
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mortality in patients with cardiogenic shock associated with the use of microaxial flow pump: a systematic review and meta-analysis

Edgar D. Guzmán-Ríos, Marco F. Flores-Reyes, Erick Ramírez-García, Lenyn D. Montes-Sevilla et al.
Archivos de cardiolog�a de M�xico (English ed Internet)
Mechanical Circulatory Support Devices
article

Mortality in patients with cardiogenic shock associated with the use of microaxial flow pump: a systematic review and meta-analysis

Edgar D. Guzmán-Ríos, Marco F. Flores-Reyes, Erick Ramírez-García, Lenyn D. Montes-Sevilla, Gilberto H. Acosta-Gutiérrez, Osmara Morales-Hernández, Paul E. Hernández-Montes
article en

Abstract

In this article we aim to evaluate the impact of the microaxial flow pump on mortality in patients with cardiogenic shock associated with acute myocardial infarction through a systematic review and meta-analysis of clinical trials and cohort studies.Patients with acute myocardial infarction, both with and without ST-segment elevation, associated with cardiogenic shock and treated with a microaxial flow pump, were included.Mortality data and implantation time of the device were reported.Patients with more than 24 hours of shock progression, those with other shock etiologies, patients with mechanical complications from acute myocardial infarction, and other comorbidity, were excluded.The search was conducted in PubMed and Web of Science databases for articles published from 2019 until November 10, 2024.Risk of bias was evaluated using the RoB 2 tool and the ROBINS-E, while statistical analysis was performed using Review Manager 5.4.1 software.A total of 1,000 patients from five studies were included.The use of the microaxial flow pump was associated with a reduction in mortality compared to placebo (OR: 0.6; 95% CI: 0.42-0.85;p = 0.005).However, there were no significant differences in mortality related to the timing of the microaxial flow pump implantation (before, during, or after percutaneous coronary intervention) (OR: 0.85; 95% CI: 0.59-1.22;p = 0.37).Patients with cardiogenic shock have gained access to various treatment opportunities that were not available until recently.The results suggest that the microaxial flow pump is a therapeutic option in these patients with significant effects on mortality.

Archivos de cardiolog�a de M�xico (English ed Internet)Vol. 96(1)
Good health and well-being
Openalex Percentile: Top 9%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.