Single-use bronchoscopes for pleural cavity access: cadaveric feasibility study

We conducted a cadaveric feasibility study of two intrapleural applications of single-use bronchoscopes. In Approach 1, a 2.7 mm bronchoscope was used as a visual stylet inside a 20-Fr trocar catheter to confirm pleural entry and drain-tip position. In Approach 2, a 5.0 mm bronchoscope was used as a flexible thoracoscope for limited pleural inspection, aspiration, and direct-vision forceps biopsy; a sprayed-instillation maneuver was performed only to confirm technical deliverability. Approach 1 was attempted and feasible in six hemithoraces of three Thiel-embalmed cadavers. Approach 2 was attempted and feasible in four hemithoraces; it was not attempted in two hemithoraces due to time constraints and a large persistent air leak after Approach (1) No negative-to-positive conversion (new persistent air leak) was observed after Approach (2) These techniques may offer complementary approaches to conventional methods for observing the intrathoracic space and therefore warrant stepwise clinical validation.

Authors

Institutions

Publication Details

Journal
General Thoracic and Cardiovascular Surgery
Published
2026-05-11
DOI
https://doi.org/10.1007/s11748-026-02309-4
Primary Topic
Pleural and Pulmonary Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single-use bronchoscopes for pleural cavity access: cadaveric feasibility study

Yuki Sata, Hiroki Imabayashi, Takane Suzuki, Kazuhisa Tanaka et al.
General Thoracic and Cardiovascular Surgery
Pleural and Pulmonary Diseases
article

Single-use bronchoscopes for pleural cavity access: cadaveric feasibility study

Yuki Sata, Hiroki Imabayashi, Takane Suzuki, Kazuhisa Tanaka, Hidemi Suzuki, Terunaga Inage
article en

Abstract

We conducted a cadaveric feasibility study of two intrapleural applications of single-use bronchoscopes. In Approach 1, a 2.7 mm bronchoscope was used as a visual stylet inside a 20-Fr trocar catheter to confirm pleural entry and drain-tip position. In Approach 2, a 5.0 mm bronchoscope was used as a flexible thoracoscope for limited pleural inspection, aspiration, and direct-vision forceps biopsy; a sprayed-instillation maneuver was performed only to confirm technical deliverability. Approach 1 was attempted and feasible in six hemithoraces of three Thiel-embalmed cadavers. Approach 2 was attempted and feasible in four hemithoraces; it was not attempted in two hemithoraces due to time constraints and a large persistent air leak after Approach (1) No negative-to-positive conversion (new persistent air leak) was observed after Approach (2) These techniques may offer complementary approaches to conventional methods for observing the intrathoracic space and therefore warrant stepwise clinical validation.

General Thoracic and Cardiovascular Surgery
Chiba University (JP)
Openalex Percentile: Top 6%
Pleural and Pulmonary Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.