Intracardiac neuromodulation of pacemaker rate in the adult zebrafish heart in vitro

Heart rate (HR) in vertebrates is determined by the discharge frequency of cardiac pacemaker cells, which are innervated by the autonomic nervous system. The portion of this system located within the heart, the intracardiac nervous system (ICNS), transmits impulses to cardiac effectors for control of cardiac output. Central autonomic neurons modulate the heart through sympathetic (acceleratory) and parasympathetic (inhibitory) axons in the vagosympathetic trunks. In the classical model of cardiac control, the balance between sympathetic and parasympathetic efferent signals determines HR. Recent evidence of spontaneous neural activity within the ICNS in isolated hearts suggests a local regulatory element incardiac control. We examined the potential for ICNS modulation of HR in the isolated zebrafish heart, using atropine to block parasympathetic drive to the pacemaker, and timolol to block sympathetic drive. Atropine (3, 10, 30 µM) evoked tachycardia of similar magnitude at 22 and 28 ° C. Timolol (3, 10 and 30 µM) caused bradycardia at both temperatures, with greater proportional HR responses to all doses at the higher temperature. Our results suggest that both sympathetic and parasympathetic outputs from the ICNS influence the pacemaker, with the degree of sympathetic drive being temperature-sensitive. Intrinsic HR, obtained after dual antagonist application, was not significantly different from HR before drug application so the effects of sympathetic and parasympathetic drive on pacemaker rate appeared to be evenly balanced. We propose that the ICNS in the isolated zebrafish heart is capable of modulating HR in the absence of extracardiac autonomic inputs.

Authors

Institutions

Publication Details

Journal
American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Published
2026-05-11
DOI
https://doi.org/10.1152/ajpregu.00298.2025
Primary Topic
Zebrafish Biomedical Research Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intracardiac neuromodulation of pacemaker rate in the adult zebrafish heart in vitro

Frank M. Smith, Zachary D. Long, Keegan P. D. O'Shea
American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Zebrafish Biomedical Research Applications
article

Intracardiac neuromodulation of pacemaker rate in the adult zebrafish heart in vitro

Frank M. Smith, Zachary D. Long, Keegan P. D. O'Shea
article en

Abstract

Heart rate (HR) in vertebrates is determined by the discharge frequency of cardiac pacemaker cells, which are innervated by the autonomic nervous system. The portion of this system located within the heart, the intracardiac nervous system (ICNS), transmits impulses to cardiac effectors for control of cardiac output. Central autonomic neurons modulate the heart through sympathetic (acceleratory) and parasympathetic (inhibitory) axons in the vagosympathetic trunks. In the classical model of cardiac control, the balance between sympathetic and parasympathetic efferent signals determines HR. Recent evidence of spontaneous neural activity within the ICNS in isolated hearts suggests a local regulatory element incardiac control. We examined the potential for ICNS modulation of HR in the isolated zebrafish heart, using atropine to block parasympathetic drive to the pacemaker, and timolol to block sympathetic drive. Atropine (3, 10, 30 µM) evoked tachycardia of similar magnitude at 22 and 28 ° C. Timolol (3, 10 and 30 µM) caused bradycardia at both temperatures, with greater proportional HR responses to all doses at the higher temperature. Our results suggest that both sympathetic and parasympathetic outputs from the ICNS influence the pacemaker, with the degree of sympathetic drive being temperature-sensitive. Intrinsic HR, obtained after dual antagonist application, was not significantly different from HR before drug application so the effects of sympathetic and parasympathetic drive on pacemaker rate appeared to be evenly balanced. We propose that the ICNS in the isolated zebrafish heart is capable of modulating HR in the absence of extracardiac autonomic inputs.

American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Dalhousie University (CA)
Natural Sciences and Engineering Research Council of Canada
Good health and well-being
Openalex Percentile: Top 8%
Zebrafish Biomedical Research Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.