Accuracy of Fluoroscopic Navigation for Predicting Leg Length and Offset in Primary Hip Arthroplasty.

BACKGROUND: Fluoroscopic-assisted computer navigation is widely used to guide intraoperative decisions on leg length (LL) and offset in primary total hip arthroplasty (THA), but its accuracy remains under-evaluated. This study assessed the precision of a fluoroscopy-based navigation system by comparing its intraoperative predictions to validated postoperative measurements. METHODS: We retrospectively reviewed 490 consecutive primary THA cases performed by three surgeons at a tertiary academic center. Intraoperative changes in leg length and offset using a fluoroscopic navigation system were recorded. Pre- and postoperative antero-posterior pelvis radiographs were measured using an artificial intelligence (AI)-based algorithm to determine actual changes in LL and offset. Navigated and radiographic values were compared using mean/median differences and by percentage of cases within clinically relevant thresholds: ± three mm, ± five mm, and ± 10 mm. RESULTS: For leg length, postoperative AI-based measurements showed a mean change of 4.1 ± 5.6 mm (median 3.7), while the intraoperative navigation system predicted a mean change of 2.5 ± 3.1 mm (median two, P < 0.0001). Navigation underestimated leg length change on average. Predictions were within ± three mm in 65.8% of cases, ± five mm in 86.0%, and ± 10 mm in 98.5%.For femoral offset, AI-based measurements showed a mean postoperative change of 1.7 ± 5.4 mm (median 1.6), compared with a mean predicted change of 3.4 ± 5.0 mm (median three) from navigation (P < 0.0001). Navigation overestimated offset change on average. Accuracy was within ± three mm in 44.1% of cases, ± five mm in 64.9%, and ± 10 mm in 93.9%. CONCLUSION: Although the fluoroscopy-based navigation system showed statistically significant differences from postoperative radiographic measurements, it achieved clinically acceptable accuracy in most cases. These findings support the system's utility in guiding THA while emphasizing the importance of intraoperative awareness of its limitations.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2026-05-08
DOI
https://doi.org/10.1016/j.arth.2026.04.110
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of Fluoroscopic Navigation for Predicting Leg Length and Offset in Primary Hip Arthroplasty.

John R. Dunn, Michael P Murphy, Patrick Kelly, Grant Hamilton et al.
PubMed
Orthopaedic implants and arthroplasty
article

Accuracy of Fluoroscopic Navigation for Predicting Leg Length and Offset in Primary Hip Arthroplasty.

John R. Dunn, Michael P Murphy, Patrick Kelly, Grant Hamilton, William G Hamilton, Addison Clift
article en

Abstract

BACKGROUND: Fluoroscopic-assisted computer navigation is widely used to guide intraoperative decisions on leg length (LL) and offset in primary total hip arthroplasty (THA), but its accuracy remains under-evaluated. This study assessed the precision of a fluoroscopy-based navigation system by comparing its intraoperative predictions to validated postoperative measurements. METHODS: We retrospectively reviewed 490 consecutive primary THA cases performed by three surgeons at a tertiary academic center. Intraoperative changes in leg length and offset using a fluoroscopic navigation system were recorded. Pre- and postoperative antero-posterior pelvis radiographs were measured using an artificial intelligence (AI)-based algorithm to determine actual changes in LL and offset. Navigated and radiographic values were compared using mean/median differences and by percentage of cases within clinically relevant thresholds: ± three mm, ± five mm, and ± 10 mm. RESULTS: For leg length, postoperative AI-based measurements showed a mean change of 4.1 ± 5.6 mm (median 3.7), while the intraoperative navigation system predicted a mean change of 2.5 ± 3.1 mm (median two, P < 0.0001). Navigation underestimated leg length change on average. Predictions were within ± three mm in 65.8% of cases, ± five mm in 86.0%, and ± 10 mm in 98.5%.For femoral offset, AI-based measurements showed a mean postoperative change of 1.7 ± 5.4 mm (median 1.6), compared with a mean predicted change of 3.4 ± 5.0 mm (median three) from navigation (P < 0.0001). Navigation overestimated offset change on average. Accuracy was within ± three mm in 44.1% of cases, ± five mm in 64.9%, and ± 10 mm in 93.9%. CONCLUSION: Although the fluoroscopy-based navigation system showed statistically significant differences from postoperative radiographic measurements, it achieved clinically acceptable accuracy in most cases. These findings support the system's utility in guiding THA while emphasizing the importance of intraoperative awareness of its limitations.

PubMed
Anderson Orthopaedic Research Institute (US)
Openalex Percentile: Top 4%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.