Sternal re-Closure for refractory dehiscence using ultra-high molecular weight polyethylene tape
Abstract Ultra-high molecular weight polyethylene tape has been introduced as an alternative to stainless-steel wires for primary sternal closure, yet its efficacy in secondary reconstruction has not been reported. We present a 67-year-old male with refractory sternal dehiscence following coronary artery bypass grafting. Despite two failed reconstruction attempts using conventional wires and the Robicsek technique, stable fixation was finally achieved by combining ultra-high molecular weight polyethylene tape with mesh plates. This case highlights the potential utility of ultra-high molecular weight polyethylene tape as a durable and secure option for secondary sternal closure in patients with refractory sternal dehiscence.
Authors
- Yoshinori Nakahara (ORCID: https://orcid.org/0000-0002-0766-5166)
- Tomohiro Iwakura (ORCID: https://orcid.org/0000-0003-0733-0099)
- Taiki Niki (ORCID: https://orcid.org/0009-0002-0734-7333)
- Akira Marui
Institutions
- Sakakibara Hospital (JP)
Publication Details
- Journal
- Interdisciplinary CardioVascular and Thoracic Surgery
- Published
- 2026-05-09
- DOI
- https://doi.org/10.1093/icvts/ivag141
- Primary Topic
- Surgical site infection prevention
- Type
- article
- Field-Weighted Citation Impact
- 0.00