Enhancing LC-MS method sensitivity for the quantification of 5-nitroimidazoles in animal liver using high-field asymmetric waveform ion mobility spectrometry (FAIMS)

To help protect the Canadian food supply, liquid chromatography – mass spectrometry (LC-MS) methods are used by the Canadian Food Inspection Agency (CFIA) to quantify veterinary drug residues (VDRs) in tissues of food animals. Some veterinary drugs are banned for use in food producing animals in Canada because of adverse health risks for humans, and for these drugs, the desire is to create the most sensitive methods possible. The use of 5-nitroimidazoles in food animals is banned in Canada and other jurisdictions because of their toxic adverse effects. Currently, the CFIA doesn’t have a method for 5-nitroimidazoles in animal liver and a highly sensitive method is desired. The development of a method for 5-nitroimidazoles in animal liver is reported for 9, 5-nitroimidazoles using LC-multiple reaction monitoring (MRM) on a triple quadrupole MS, with and without high-field asymmetric waveform ion mobility spectrometry (FAIMS). With LC-MRM, the chemical background was problematic for four analytes in particular, resulting in higher limit of quantification (LOQ) and limit of detection (LOD) values compared with LC-FAIMS-MRM. With FAIMS, all 9, 5-nitroimidazoles could be detected at an LOQ of 0.125 ng/g and 6 had an LOD of 0.031 ng/g. Furthermore, since FAIMS filters the majority of chemical background in the gas-phase, LC-FAIMS-MRM is more tolerant to changes in the liver matrix resulting in a more robust analysis. In particular, changes in the liver matrix affected LOQ values using LC-MRM for five of the analytes, whereas the LOQ values were unaffected using LC-FAIMS-MRM.

Authors

Institutions

Publication Details

Journal
Canadian Journal of Chemistry
Published
2026-05-11
DOI
https://doi.org/10.1139/cjc-2026-0020
Primary Topic
Pesticide Residue Analysis and Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing LC-MS method sensitivity for the quantification of 5-nitroimidazoles in animal liver using high-field asymmetric waveform ion mobility spectrometry (FAIMS)

Jana Kinar, Bryn Shurmer, Randall Purves
Canadian Journal of Chemistry
Pesticide Residue Analysis and Safety
article

Enhancing LC-MS method sensitivity for the quantification of 5-nitroimidazoles in animal liver using high-field asymmetric waveform ion mobility spectrometry (FAIMS)

Jana Kinar, Bryn Shurmer, Randall Purves
article en

Abstract

To help protect the Canadian food supply, liquid chromatography – mass spectrometry (LC-MS) methods are used by the Canadian Food Inspection Agency (CFIA) to quantify veterinary drug residues (VDRs) in tissues of food animals. Some veterinary drugs are banned for use in food producing animals in Canada because of adverse health risks for humans, and for these drugs, the desire is to create the most sensitive methods possible. The use of 5-nitroimidazoles in food animals is banned in Canada and other jurisdictions because of their toxic adverse effects. Currently, the CFIA doesn’t have a method for 5-nitroimidazoles in animal liver and a highly sensitive method is desired. The development of a method for 5-nitroimidazoles in animal liver is reported for 9, 5-nitroimidazoles using LC-multiple reaction monitoring (MRM) on a triple quadrupole MS, with and without high-field asymmetric waveform ion mobility spectrometry (FAIMS). With LC-MRM, the chemical background was problematic for four analytes in particular, resulting in higher limit of quantification (LOQ) and limit of detection (LOD) values compared with LC-FAIMS-MRM. With FAIMS, all 9, 5-nitroimidazoles could be detected at an LOQ of 0.125 ng/g and 6 had an LOD of 0.031 ng/g. Furthermore, since FAIMS filters the majority of chemical background in the gas-phase, LC-FAIMS-MRM is more tolerant to changes in the liver matrix resulting in a more robust analysis. In particular, changes in the liver matrix affected LOQ values using LC-MRM for five of the analytes, whereas the LOQ values were unaffected using LC-FAIMS-MRM.

Canadian Journal of Chemistry
Canadian Food Inspection Agency (CA), University of Saskatchewan (CA)
Openalex Percentile: Top 7%
Pesticide Residue Analysis and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.