A Comparison of Cost-Effective Sensors for a Fluorescence-Based Detection System Used in Biodiagnostic Devices

Cost-effective, fluorescence-based biodiagnostic devices have the potential to expand point-of-care (POC) testing in resource-limited settings, thereby creating new opportunities for accessible and decentralised diagnostics. The objective of this study is to investigate the performance of a newly designed and simplified system that uses several cost-effective sensors for use in a fluorescence-based biodiagnostic setup. A collecting setup that includes an elliptical mirror to focus emitted fluorescence onto the semiconductor sensors was designed for an intensity-based readout. The readout was realised by various photodiodes, photoresistors, phototransistors and one multi-pixel photon counter (MPPC). Over a range of fluorophore concentrations using serial dilutions of Rhodamine B (RhB), the limit of detection (LOD) and limit of quantification (LOQ) at system level were evaluated. With the exception of the photodiodes, the system demonstrated promising performance with all sensors. The system using the photoresistors achieved the lowest LOD but showed limited repeatability, while the system using the MPPC and phototransistors exhibited high repeatability. A proof-of-concept demonstrated the feasibility of a photoresistor-based configuration by using a sandwich immunoassay for the detection of the antigen Human Epidermal growth factor Receptor 2 (HER2) (100 nM). While this study has not yet encompassed the full spectrum of clinically relevant concentrations, it has yielded valuable insights to enable further enhancements, without the necessity for highly specialised or costly equipment. The limitations and necessary improvements for further developments are discussed.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2026-05-11
DOI
https://doi.org/10.3390/bios16050276
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Comparison of Cost-Effective Sensors for a Fluorescence-Based Detection System Used in Biodiagnostic Devices

Moritz Hemmer, Thomas Guenther, Bastian Stollfuss, André Zimmermann et al.
Biosensors
Biosensors and Analytical Detection
article

A Comparison of Cost-Effective Sensors for a Fluorescence-Based Detection System Used in Biodiagnostic Devices

Moritz Hemmer, Thomas Guenther, Bastian Stollfuss, André Zimmermann, Rebecca Vornweg, Ann-Kathrin Löffler, Roland E. Kontermann, Christian Decool
article en

Abstract

Cost-effective, fluorescence-based biodiagnostic devices have the potential to expand point-of-care (POC) testing in resource-limited settings, thereby creating new opportunities for accessible and decentralised diagnostics. The objective of this study is to investigate the performance of a newly designed and simplified system that uses several cost-effective sensors for use in a fluorescence-based biodiagnostic setup. A collecting setup that includes an elliptical mirror to focus emitted fluorescence onto the semiconductor sensors was designed for an intensity-based readout. The readout was realised by various photodiodes, photoresistors, phototransistors and one multi-pixel photon counter (MPPC). Over a range of fluorophore concentrations using serial dilutions of Rhodamine B (RhB), the limit of detection (LOD) and limit of quantification (LOQ) at system level were evaluated. With the exception of the photodiodes, the system demonstrated promising performance with all sensors. The system using the photoresistors achieved the lowest LOD but showed limited repeatability, while the system using the MPPC and phototransistors exhibited high repeatability. A proof-of-concept demonstrated the feasibility of a photoresistor-based configuration by using a sandwich immunoassay for the detection of the antigen Human Epidermal growth factor Receptor 2 (HER2) (100 nM). While this study has not yet encompassed the full spectrum of clinically relevant concentrations, it has yielded valuable insights to enable further enhancements, without the necessity for highly specialised or costly equipment. The limitations and necessary improvements for further developments are discussed.

BiosensorsVol. 16(5)
University of Stuttgart (DE), Hahn-Schickard-Gesellschaft für angewandte Forschung (DE)
Universität Stuttgart
Decent work and economic growth
Openalex Percentile: Top 10%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.