A Novel HPLC technique for the determination of casticin in pharmaceutical preparations and human plasma

This study introduces a combined HPLC and UV detection technique for the quantification of casticin in capsule and human plasma samples. The chromatographic separation was carried out utilizing a C18 column (150 mm × 4.6 mm × 5 μm) at a temperature of 25 ºC. Isocratic elution with a mobile phase comprising 60:40 v/v (methanol-0.05% formic acid) was employed. Flow rate was adjusted 1 mL/min. The analyte was determined at a wavelength of 258 nm, with a retention time of 14.7±0.01 min. The developed method underwent validation according to ICH criteria, covering specificity, linearity, precision, accuracy, detection and quantitation limits, as well as robustness. The linear range was determined to be 10-60 ng/mL for both capsule and spiked plasma specimens. The suggested technique was performed to the analysis of casticin in spiked human plasma and pharmaceutical preparations, yielding a recovery of 106.04% and demonstrating precision through intra-day and inter-day experiments with the highest relative standard deviation (RSD %) value of 4.94. Consequently, the technique was performed to the quantifying of human plasma specimens from in a patient taking medication containing casticin.

Authors

Institutions

Publication Details

Journal
Journal of Research in Pharmacy
Published
2026-05-11
DOI
https://doi.org/10.12991/jrespharm.1708765
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel HPLC technique for the determination of casticin in pharmaceutical preparations and human plasma

Gizem Tırıs, Şerife Evrim Kepekçi Tekkeli, Derya Egeli Yılmaz
Journal of Research in Pharmacy
Analytical Methods in Pharmaceuticals
article

A Novel HPLC technique for the determination of casticin in pharmaceutical preparations and human plasma

Gizem Tırıs, Şerife Evrim Kepekçi Tekkeli, Derya Egeli Yılmaz
article en

Abstract

This study introduces a combined HPLC and UV detection technique for the quantification of casticin in capsule and human plasma samples. The chromatographic separation was carried out utilizing a C18 column (150 mm × 4.6 mm × 5 μm) at a temperature of 25 ºC. Isocratic elution with a mobile phase comprising 60:40 v/v (methanol-0.05% formic acid) was employed. Flow rate was adjusted 1 mL/min. The analyte was determined at a wavelength of 258 nm, with a retention time of 14.7±0.01 min. The developed method underwent validation according to ICH criteria, covering specificity, linearity, precision, accuracy, detection and quantitation limits, as well as robustness. The linear range was determined to be 10-60 ng/mL for both capsule and spiked plasma specimens. The suggested technique was performed to the analysis of casticin in spiked human plasma and pharmaceutical preparations, yielding a recovery of 106.04% and demonstrating precision through intra-day and inter-day experiments with the highest relative standard deviation (RSD %) value of 4.94. Consequently, the technique was performed to the quantifying of human plasma specimens from in a patient taking medication containing casticin.

Journal of Research in PharmacyVol. 30(3)
Bezmiâlem Vakıf Üniversitesi (TR), Istanbul Health and Technology University, Harran University (TR)
Openalex Percentile: Top 8%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.