The Impact of Operator’s Learning Curve on the Outcomes of an Off-the-Shelf Multi-Branched Endograft for Complex and Thoracoabdominal Aneurysms Repair

Objectives: The study objectives are to evaluate the impact of the operator’s learning curve on the outcomes of off-the-shelf branched endovascular aortic repair (OTS-BEVAR) in complex and thoracoabdominal (C/TAAAs) aneurysms. Methods: Patients who underwent OTS-BEVAR (T-Branch, Cook-Medical) between 2013 and 2023 were considered. The first and last 25 cases with at least 1 year of follow-up were clustered in two groups (early experience: E.Exp.; late experience: L.Exp.) and compared. Technical success (TS), intraoperative target visceral vessel (TVV) loss, spinal cord ischemia (SCI), 30-day mortality, and TVV instability at 1 year were assessed as primary outcomes. Procedure/fluoroscopy time, iodinated contrast media (ICM) amount and length of hospitalization were assessed as secondary outcomes. A p value < 0.05 was considered statistically significant. Results: Overall, 106 cases were analyzed. Technical success was higher in L.Exp. than E.Exp. (L.Exp.: 25/25 vs. E.Exp.: 17/25; p: 0.004). Moreover, intraoperative TVVs loss was higher in E.Exp. than L.Exp. (E.Exp.: 12/25 vs. L.Exp.: 0/25; p: 0.0001). There were no differences in terms of 30-day/in-hospital mortality (E.Exp.:4/25 vs. L.Exp.:4/25; p: 1), SCI (E.Exp.:2/25 vs. L.Exp.:1/25; p: 1), and paraplegia (E.Exp.: 2/25 vs. L.Exp.: 0/25; p: 0.48) between E.Exp. and L.Exp. Cases of L.Exp. had lower fluoroscopy [E.Exp.: 160(21) vs. L.Exp.:72(18) min; p: 0.003] and overall procedure time [E.Exp.: 518(156) vs. L.Exp.:400(130) min; p: 0.04], ICM [EE: 220(45) vs. L.Exp.: 138(61) mL; p: 0.005] and hospitalization [E.Exp.: 17(9) vs. L.Exp.: 12(4) days; p: 0.03] than cases of E.Exp. Finally, patients managed in L.Exp. had lower TVVs instability at 12 months than patients managed in the E.Exp. (E.Exp.: 8/25 vs. L.Exp.: 1/25; p: 0.04). Conclusions: Cases managed in L.Exp. have higher TS, lower intraoperative TVVs loss and instability at 1-year than cases of E.Exp. Moreover, procedural/fluoroscopy time, ICM, radiation exposure and hospitalization are lower in L.Exp. than E.Exp.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-05-11
DOI
https://doi.org/10.3390/jcm15103686
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Impact of Operator’s Learning Curve on the Outcomes of an Off-the-Shelf Multi-Branched Endograft for Complex and Thoracoabdominal Aneurysms Repair

Chiara Mascoli, Rodolfo Pini, Antonio Cappiello, Paolo Spath et al.
Journal of Clinical Medicine
Aortic aneurysm repair treatments
article

The Impact of Operator’s Learning Curve on the Outcomes of an Off-the-Shelf Multi-Branched Endograft for Complex and Thoracoabdominal Aneurysms Repair

Chiara Mascoli, Rodolfo Pini, Antonio Cappiello, Paolo Spath, Carmine Poliseno, Pietro Fiorio, Marco Mattiacci, Stefania Caputo, Andrea Vacirca, Mauro Gargiulo, Gianluca Faggioli, Enrico Gallitto
article en

Abstract

Objectives: The study objectives are to evaluate the impact of the operator’s learning curve on the outcomes of off-the-shelf branched endovascular aortic repair (OTS-BEVAR) in complex and thoracoabdominal (C/TAAAs) aneurysms. Methods: Patients who underwent OTS-BEVAR (T-Branch, Cook-Medical) between 2013 and 2023 were considered. The first and last 25 cases with at least 1 year of follow-up were clustered in two groups (early experience: E.Exp.; late experience: L.Exp.) and compared. Technical success (TS), intraoperative target visceral vessel (TVV) loss, spinal cord ischemia (SCI), 30-day mortality, and TVV instability at 1 year were assessed as primary outcomes. Procedure/fluoroscopy time, iodinated contrast media (ICM) amount and length of hospitalization were assessed as secondary outcomes. A p value < 0.05 was considered statistically significant. Results: Overall, 106 cases were analyzed. Technical success was higher in L.Exp. than E.Exp. (L.Exp.: 25/25 vs. E.Exp.: 17/25; p: 0.004). Moreover, intraoperative TVVs loss was higher in E.Exp. than L.Exp. (E.Exp.: 12/25 vs. L.Exp.: 0/25; p: 0.0001). There were no differences in terms of 30-day/in-hospital mortality (E.Exp.:4/25 vs. L.Exp.:4/25; p: 1), SCI (E.Exp.:2/25 vs. L.Exp.:1/25; p: 1), and paraplegia (E.Exp.: 2/25 vs. L.Exp.: 0/25; p: 0.48) between E.Exp. and L.Exp. Cases of L.Exp. had lower fluoroscopy [E.Exp.: 160(21) vs. L.Exp.:72(18) min; p: 0.003] and overall procedure time [E.Exp.: 518(156) vs. L.Exp.:400(130) min; p: 0.04], ICM [EE: 220(45) vs. L.Exp.: 138(61) mL; p: 0.005] and hospitalization [E.Exp.: 17(9) vs. L.Exp.: 12(4) days; p: 0.03] than cases of E.Exp. Finally, patients managed in L.Exp. had lower TVVs instability at 12 months than patients managed in the E.Exp. (E.Exp.: 8/25 vs. L.Exp.: 1/25; p: 0.04). Conclusions: Cases managed in L.Exp. have higher TS, lower intraoperative TVVs loss and instability at 1-year than cases of E.Exp. Moreover, procedural/fluoroscopy time, ICM, radiation exposure and hospitalization are lower in L.Exp. than E.Exp.

Journal of Clinical MedicineVol. 15(10)
IRCCS Azienda Ospedliero-Universitaria di Bologna Policlinico di Sant'Orsola (IT), Azienda USL di Bologna (IT), University of Bologna (IT)
Good health and well-being
Openalex Percentile: Top 7%
Aortic aneurysm repair treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.