Distribution Network Fault Location Method Based on Limited Measurement Information

Due to the complex structure and large number of nodes in distribution networks, it is difficult to achieve full coverage of synchronous phasor measurement units (μPMUs) in actual engineering projects, resulting in limited available measurement data. To address this issue, this paper proposes a distribution network fault location method based on limited measurement information. First, the distribution characteristics of the node positive-sequence voltage measurement deviation (NPSVMD) following a fault occurrence are analyzed. On this basis, a principle for faulted line identification is established by exploiting the common-path property between the measurement point exhibiting the maximum NPSVMD and the reference node. Furthermore, the fault current is equivalently derived using the nodal voltage variation equations (NVVE), and a distance estimation function is constructed by incorporating the NPSVMD values at the measurement nodes on both sides of the faulted line, thereby enabling accurate determination of the fault location. Simulations on the IEEE 33-bus distribution system verify that the proposed method can accurately identify the faulted line and achieve high-precision distance estimation using limited measurement information, demonstrating strong robustness and superior adaptability.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-05-11
DOI
https://doi.org/10.3390/electronics15102044
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Distribution Network Fault Location Method Based on Limited Measurement Information

Wen Xu, Ying Liu, Kui Chen, Yuheng Yang et al.
Electronics
Power Systems Fault Detection
article

Distribution Network Fault Location Method Based on Limited Measurement Information

Wen Xu, Ying Liu, Kui Chen, Yuheng Yang, Wenhao Zhu
article en

Abstract

Due to the complex structure and large number of nodes in distribution networks, it is difficult to achieve full coverage of synchronous phasor measurement units (μPMUs) in actual engineering projects, resulting in limited available measurement data. To address this issue, this paper proposes a distribution network fault location method based on limited measurement information. First, the distribution characteristics of the node positive-sequence voltage measurement deviation (NPSVMD) following a fault occurrence are analyzed. On this basis, a principle for faulted line identification is established by exploiting the common-path property between the measurement point exhibiting the maximum NPSVMD and the reference node. Furthermore, the fault current is equivalently derived using the nodal voltage variation equations (NVVE), and a distance estimation function is constructed by incorporating the NPSVMD values at the measurement nodes on both sides of the faulted line, thereby enabling accurate determination of the fault location. Simulations on the IEEE 33-bus distribution system verify that the proposed method can accurately identify the faulted line and achieve high-precision distance estimation using limited measurement information, demonstrating strong robustness and superior adaptability.

ElectronicsVol. 15(10)
China University of Mining and Technology (CN)
Industry, innovation and infrastructure
Openalex Percentile: Top 7%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.