Left ventricular outflow tract diameter variability and prosthesis-patient mismatch: a simulation study

Abstract A recent discussion that highlighted the differences between the reported effective orifice area and corresponding incidence of prosthesis-patient mismatch within the 1- and 7-year results of the PERIcardial SurGical AOrtic Valve ReplacemeNt (PERIGON) Trial of the Avalus valve has once again emphasized the instability of such measurements. The effective orifice area, calculated using the continuity equation through measurements of the left ventricular outflow tract diameter, is highly susceptible to measurement variability, as previously demonstrated in literature through both intra- and interobserver variability. To illustrate this problem a simulation was performed in which the left ventricular outflow tract diameter was systematically altered by -2 mm, -1 mm, 0 mm, +1 mm, and +2 mm. Subsequently, the proportion of severe prosthesis-patient mismatch was recalculated and varied between 13.3%, 6.2%, 3.1% (original), 1.2%, and 0.3%, respectively. These findings demonstrate that small but clinically realistic variability in left ventricular outflow tract measurements can significantly affect the presence of prosthesis-patient mismatch. A measurement variability of 1 mm can nearly double or halve the prevalence of severe prosthesis-patient mismatch. This illustrates that prosthesis-patient mismatch, in its current form, is highly unstable and that indexed effective orifice area-based prosthesis-patient mismatch should not be used in isolation.

Authors

Institutions

Publication Details

Journal
Interdisciplinary CardioVascular and Thoracic Surgery
Published
2026-05-08
DOI
https://doi.org/10.1093/icvts/ivag133
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Left ventricular outflow tract diameter variability and prosthesis-patient mismatch: a simulation study

Joseph F. Sabik, Michiel D. Vriesendorp, Saki Ito, Bart J J Velders et al.
Interdisciplinary CardioVascular and Thoracic Surgery
Cardiac Valve Diseases and Treatments
article

Left ventricular outflow tract diameter variability and prosthesis-patient mismatch: a simulation study

Joseph F. Sabik, Michiel D. Vriesendorp, Saki Ito, Bart J J Velders, Robert J M Klautz, Jae K Oh, J W Taco Boltje
article en

Abstract

Abstract A recent discussion that highlighted the differences between the reported effective orifice area and corresponding incidence of prosthesis-patient mismatch within the 1- and 7-year results of the PERIcardial SurGical AOrtic Valve ReplacemeNt (PERIGON) Trial of the Avalus valve has once again emphasized the instability of such measurements. The effective orifice area, calculated using the continuity equation through measurements of the left ventricular outflow tract diameter, is highly susceptible to measurement variability, as previously demonstrated in literature through both intra- and interobserver variability. To illustrate this problem a simulation was performed in which the left ventricular outflow tract diameter was systematically altered by -2 mm, -1 mm, 0 mm, +1 mm, and +2 mm. Subsequently, the proportion of severe prosthesis-patient mismatch was recalculated and varied between 13.3%, 6.2%, 3.1% (original), 1.2%, and 0.3%, respectively. These findings demonstrate that small but clinically realistic variability in left ventricular outflow tract measurements can significantly affect the presence of prosthesis-patient mismatch. A measurement variability of 1 mm can nearly double or halve the prevalence of severe prosthesis-patient mismatch. This illustrates that prosthesis-patient mismatch, in its current form, is highly unstable and that indexed effective orifice area-based prosthesis-patient mismatch should not be used in isolation.

Interdisciplinary CardioVascular and Thoracic Surgery
Mayo Clinic (US), University Hospitals of Cleveland (US), Leiden University Medical Center (NL), Amsterdam Neuroscience (NL), Mayo Clinic in Arizona (US), Amsterdam University Medical Centers (NL), University of Amsterdam (NL)
Openalex Percentile: Top 5%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.