Disaggregation of Space-Heating load in buildings from hourly Smart-Meter data using a hybrid ICA–PLR approach

Space-heating dominates electricity consumption in Norwegian public buildings, yet hourly space-heating load (SHL) is rarely sub-metered, limiting monitoring and demand response (DR). The objective of this study is to develop and evaluate a physics-guided, scalable method to disaggregate hourly SHL from whole-building hourly electric load using only weather and calendar information, without SHL sub-metering. Specifically, this study evaluates the performance of a hybrid ICA-PLR estimator for hourly SHL disaggregation against PLR, RFR, and FastICA benchmarks. This study presents a hybrid disaggregation framework that couples Independent Component Analysis (ICA) with a heating-degree-hour piecewise linear regression (HDH-PLR) under a temperature- and schedule-aware cold-hour mask. ICA extracts a heating-like latent component from cold-hour residuals across multiple buildings; HDH-PLR re-anchors scale and slope to a physics-consistent temperature signature; and mask gating with lag, seasonal, and weekend factors suppresses warm-weather false activation. The proposed framework requires only hourly smart-meter, weather, and calendar data. The method is applied to a portfolio of 22 public buildings (schools, kindergartens, offices, and institutions). All quantitative validation is performed on a sub-metered validation subset of 5 buildings using hourly SHL as ground truth. Across the validation subset, results indicate that hourly accuracy reaches R 2 ≈ 0.91 with nMAE ≈ 13 % to 14 %, while estimated hourly SHL remains near zero during summer periods. At the building level in the validation subset, the method tracks morning recovery, night setbacks, and cold-spell amplitudes with fewer mild-weather false positives than the benchmark techniques. The approach yields interpretable parameters (balance temperature, lag, seasonal/weekend factors) that support weather-normalized monitoring and flexibility operations in public building portfolios. This work demonstrates that physics-guided disaggregation can extend operational visibility of public-building heating systems using only utility-grade data and support weather-normalized monitoring and flexibility planning across public-building portfolios.

Authors

Institutions

Publication Details

Journal
Energy and Buildings
Published
2026-05-01
DOI
https://doi.org/10.1016/j.enbuild.2026.117618
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Disaggregation of Space-Heating load in buildings from hourly Smart-Meter data using a hybrid ICA–PLR approach

Nand Kishor, Abdullah Jamal, Anna Mutale
Energy and Buildings
Building Energy and Comfort Optimization
article

Disaggregation of Space-Heating load in buildings from hourly Smart-Meter data using a hybrid ICA–PLR approach

Nand Kishor, Abdullah Jamal, Anna Mutale
article en

Abstract

Space-heating dominates electricity consumption in Norwegian public buildings, yet hourly space-heating load (SHL) is rarely sub-metered, limiting monitoring and demand response (DR). The objective of this study is to develop and evaluate a physics-guided, scalable method to disaggregate hourly SHL from whole-building hourly electric load using only weather and calendar information, without SHL sub-metering. Specifically, this study evaluates the performance of a hybrid ICA-PLR estimator for hourly SHL disaggregation against PLR, RFR, and FastICA benchmarks. This study presents a hybrid disaggregation framework that couples Independent Component Analysis (ICA) with a heating-degree-hour piecewise linear regression (HDH-PLR) under a temperature- and schedule-aware cold-hour mask. ICA extracts a heating-like latent component from cold-hour residuals across multiple buildings; HDH-PLR re-anchors scale and slope to a physics-consistent temperature signature; and mask gating with lag, seasonal, and weekend factors suppresses warm-weather false activation. The proposed framework requires only hourly smart-meter, weather, and calendar data. The method is applied to a portfolio of 22 public buildings (schools, kindergartens, offices, and institutions). All quantitative validation is performed on a sub-metered validation subset of 5 buildings using hourly SHL as ground truth. Across the validation subset, results indicate that hourly accuracy reaches R 2 ≈ 0.91 with nMAE ≈ 13 % to 14 %, while estimated hourly SHL remains near zero during summer periods. At the building level in the validation subset, the method tracks morning recovery, night setbacks, and cold-spell amplitudes with fewer mild-weather false positives than the benchmark techniques. The approach yields interpretable parameters (balance temperature, lag, seasonal/weekend factors) that support weather-normalized monitoring and flexibility operations in public building portfolios. This work demonstrates that physics-guided disaggregation can extend operational visibility of public-building heating systems using only utility-grade data and support weather-normalized monitoring and flexibility planning across public-building portfolios.

Energy and Buildings
Riga Technical University (LV), Fredrikstad Energi (Norway) (NO)
Sustainable cities and communities
Openalex Percentile: Top 6%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.