Reconfigurable Multichannel Glass Nanopores Speed up DNA and MicroRNA Detection

Nanopore sensing is a promising platform for single-molecule analysis. However, the intrinsically low capture rate of individual nanopores constrains its utility, resulting in prolonged time-to-result for low-concentration biomarkers. We address this challenge by implementing reconfigurable parallel measurements across glass nanopore arrays using a single high-bandwidth amplifier. Our results demonstrate that the capture rate scales linearly with the nanopore count, accelerating subpicomolar DNA detection and enabling sufficient events for statistical analysis within a 15 min measurement. We also elucidate the correlation between noise level and nanopore count. To validate the platform's diagnostic potential, we employed DNA carriers for low-abundance miRNA analysis, achieving detection of 2 pM targets in a 10 μL sample and shortening the detection time to ∼45 min, compared with the ∼12 h required for single glass nanopore measurements at ∼50 pM. These results highlight the potential of glass nanopore arrays as a promising platform for next-generation early disease diagnostics.

Authors

Institutions

Publication Details

Journal
Nano Letters
Published
2026-05-11
DOI
https://doi.org/10.1021/acs.nanolett.5c05670
Primary Topic
Nanopore and Nanochannel Transport Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reconfigurable Multichannel Glass Nanopores Speed up DNA and MicroRNA Detection

Y T Li, Kaikai Chen, Zhongfei Liu, Ying Liu et al.
Nano Letters
Nanopore and Nanochannel Transport Studies
article

Reconfigurable Multichannel Glass Nanopores Speed up DNA and MicroRNA Detection

Y T Li, Kaikai Chen, Zhongfei Liu, Ying Liu, Ulrich F. Keyser, Yuxia Nie, Rui Hu
article en

Abstract

Nanopore sensing is a promising platform for single-molecule analysis. However, the intrinsically low capture rate of individual nanopores constrains its utility, resulting in prolonged time-to-result for low-concentration biomarkers. We address this challenge by implementing reconfigurable parallel measurements across glass nanopore arrays using a single high-bandwidth amplifier. Our results demonstrate that the capture rate scales linearly with the nanopore count, accelerating subpicomolar DNA detection and enabling sufficient events for statistical analysis within a 15 min measurement. We also elucidate the correlation between noise level and nanopore count. To validate the platform's diagnostic potential, we employed DNA carriers for low-abundance miRNA analysis, achieving detection of 2 pM targets in a 10 μL sample and shortening the detection time to ∼45 min, compared with the ∼12 h required for single glass nanopore measurements at ∼50 pM. These results highlight the potential of glass nanopore arrays as a promising platform for next-generation early disease diagnostics.

Nano Letters
University of Cambridge (GB), Center for NanoScience (DE), Cavendish Hospital (GB), University of Chinese Academy of Sciences (CN)
UK Research and Innovation, National Natural Science Foundation of China, European Research Council, Beijing Municipal Natural Science Foundation, National Key Research and Development Program of China
Openalex Percentile: Top 10%
Nanopore and Nanochannel Transport Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Reconfigurable Multichannel Glass Nanopores Speed up DNA and MicroRNA Detection — Y T Li, Kaikai Chen, et al. · Nano Letters (2026) | TGRS Research Map | TGRS