Methods of Inner Filter Effect Correction in Fluorescence Measurements of Protein–Ligand Association: A Re‐Examination of the Association of Anti‐HIV Drugs to Serum Albumin

Fluorescence‐based methods are widely used to assess protein–ligand and protein–protein interactions. Thanks to their high sensitivity, these techniques allow very low dissociation constants to be determined. However, in some cases, results must be critically revised because some artifacts can occur, one of the most common being the inner filter effect (IFE). In this article, we show how multiple strategies should be used to correct data obtained from fluorescence quenching experiments to avoid overestimation of binding affinities. The extent of the proposed corrections will depend on the spectroscopic properties of the protein and the ligand, i.e., the fluorophore involved in the experiments, as well as on the specific experimental conditions in each case.

Authors

Institutions

Publication Details

Journal
Chemistry - Methods
Published
2026-05-01
DOI
https://doi.org/10.1002/cmtd.70094
Primary Topic
Protein Interaction Studies and Fluorescence Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Methods of Inner Filter Effect Correction in Fluorescence Measurements of Protein–Ligand Association: A Re‐Examination of the Association of Anti‐HIV Drugs to Serum Albumin

Filippo Savini, Sara Bobone, Alessio Bocedi, Lorenzo Stella et al.
Chemistry - Methods
Protein Interaction Studies and Fluorescence Analysis
article

Methods of Inner Filter Effect Correction in Fluorescence Measurements of Protein–Ligand Association: A Re‐Examination of the Association of Anti‐HIV Drugs to Serum Albumin

Filippo Savini, Sara Bobone, Alessio Bocedi, Lorenzo Stella, Daniela Roversi
article en

Abstract

Fluorescence‐based methods are widely used to assess protein–ligand and protein–protein interactions. Thanks to their high sensitivity, these techniques allow very low dissociation constants to be determined. However, in some cases, results must be critically revised because some artifacts can occur, one of the most common being the inner filter effect (IFE). In this article, we show how multiple strategies should be used to correct data obtained from fluorescence quenching experiments to avoid overestimation of binding affinities. The extent of the proposed corrections will depend on the spectroscopic properties of the protein and the ligand, i.e., the fluorophore involved in the experiments, as well as on the specific experimental conditions in each case.

Chemistry - MethodsVol. 6(5)
University of Rome Tor Vergata (IT)
Good health and well-being
Openalex Percentile: Top 7%
Protein Interaction Studies and Fluorescence Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.