Design and Characterization of 3D Printed Auxetic PLA-HA Composite Scaffolds for Biomedical Application

Additive manufacturing (AM) techniques are becoming key factors for repairing and replacing damaged bone. These techniques enable the customization of implants, which can be tailored to the specific area to be treated or healed. Additionally, the combination of absorbable and osteoconductive biomaterials with 3D printing could eliminate second surgeries to remove implants, which is particularly relevant in pediatric and geriatric patients. The capabilities of AM in this context affect not only the external shape but also the internal microarchitecture, where the arrangement of struts to develop complex infills enhances relevant properties such as specific strength, degradation rate, and vascularization. In this study, auxetic scaffold structures made of both polylactic acid (PLA) and a PLA-hydroxyapatite (PLA-HA) composite with 40 wt% of hydroxyapatite (HA) are designed and produced using Fused Filament Fabrication (FFF). Samples of PLA and PLA-HA were 3D printed in dense samples and with auxetic infills. In dense samples, the characterization is performed by X-ray diffraction (XRD), Raman spectroscopy, wettability tests, nanoindentation, and tribological assessments. Two auxetic cellular models have been tested after degradation in PBS media, and their microstructural, structural, and mechanical properties are analyzed. Results show that the addition of hydroxyapatite (HA) significantly improves the hydrophilicity of the PLA matrix, as evidenced by a decrease in water contact angle from 73.4 ± 4.4° to 52.6 ± 2.8° (≈28% reduction), while also enhancing its mechanical and tribological properties, with hardness increasing from 207 ± 30 MPa to 241 ± 28 MPa (≈15%) and Young’s modulus from 4.08 ± 0.55 GPa to 6.24 ± 0.61 GPa (≈53%). Additionally, biodegradation of PLA-HA composites reveals a significant reduction in mechanical properties after 15 days, while the auxetic re-entrant structures mostly retain their shape during compression testing.

Authors

Institutions

Publication Details

Journal
Materials
Published
2026-05-10
DOI
https://doi.org/10.3390/ma19101972
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Characterization of 3D Printed Auxetic PLA-HA Composite Scaffolds for Biomedical Application

Djamel Miroud, Ana Ferrández-Montero, Antonio Javier Sánchez‐Herencia, Hossein Besharatloo et al.
Materials
Bone Tissue Engineering Materials
article

Design and Characterization of 3D Printed Auxetic PLA-HA Composite Scaffolds for Biomedical Application

Djamel Miroud, Ana Ferrández-Montero, Antonio Javier Sánchez‐Herencia, Hossein Besharatloo, B. Ferrari, Mohammed Amine Benziada, Isamil Daoud
article en

Abstract

Additive manufacturing (AM) techniques are becoming key factors for repairing and replacing damaged bone. These techniques enable the customization of implants, which can be tailored to the specific area to be treated or healed. Additionally, the combination of absorbable and osteoconductive biomaterials with 3D printing could eliminate second surgeries to remove implants, which is particularly relevant in pediatric and geriatric patients. The capabilities of AM in this context affect not only the external shape but also the internal microarchitecture, where the arrangement of struts to develop complex infills enhances relevant properties such as specific strength, degradation rate, and vascularization. In this study, auxetic scaffold structures made of both polylactic acid (PLA) and a PLA-hydroxyapatite (PLA-HA) composite with 40 wt% of hydroxyapatite (HA) are designed and produced using Fused Filament Fabrication (FFF). Samples of PLA and PLA-HA were 3D printed in dense samples and with auxetic infills. In dense samples, the characterization is performed by X-ray diffraction (XRD), Raman spectroscopy, wettability tests, nanoindentation, and tribological assessments. Two auxetic cellular models have been tested after degradation in PBS media, and their microstructural, structural, and mechanical properties are analyzed. Results show that the addition of hydroxyapatite (HA) significantly improves the hydrophilicity of the PLA matrix, as evidenced by a decrease in water contact angle from 73.4 ± 4.4° to 52.6 ± 2.8° (≈28% reduction), while also enhancing its mechanical and tribological properties, with hardness increasing from 207 ± 30 MPa to 241 ± 28 MPa (≈15%) and Young’s modulus from 4.08 ± 0.55 GPa to 6.24 ± 0.61 GPa (≈53%). Additionally, biodegradation of PLA-HA composites reveals a significant reduction in mechanical properties after 15 days, while the auxetic re-entrant structures mostly retain their shape during compression testing.

MaterialsVol. 19(10)
University of Sciences and Technology Houari Boumediene (DZ), Instituto de Cerámica y Vidrio (ES), Universitat Politècnica de Catalunya (ES)
Openalex Percentile: Top 8%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.