Optimizing glaucoma detection using hybrid deep-evolutionary framework from retinal images

Glaucoma represents a heterogeneous group of progressive optic neuropathies characterized by the irreversible degeneration of retinal ganglion cells and their axons, culminating in structural optic nerve head damage and permanent visual field loss. Early and accurate detection is critical for preventing permanent vision loss, yet existing automated systems suffer from inadequate generalization across diverse datasets, poor handling of class imbalance, and sub-optimal hyperparameter selection in deep learning pipelines.To address these critical clinical challenges, this research proposes a novel hybrid evolutionary-optimized deep learning framework that systematically integrates Grasshopper Optimization Algorithm (GOA) with a custom CNN-DNN architecture specifically designed for glaucoma detection from fundus images.Unlike existing approaches that rely on manual or grid-based hyperparameter tuning, our GOA-based optimization systematically navigates a 7-dimensional hyperparameter space comprising learning rate, batch size, dropout rate, number of convolutional filters, dense layer units, regularization coefficient, and optimizer types. The proposed framework is rigorously evaluated across five publicly available benchmark datasets (RIM-ONE, ACRIMA, REFUGE, ORIGA, and DRISHTI-GS) representing diverse imaging protocols, patient demographics, and class distributions. Comprehensive statistical validation using Friedman test demonstrates that the GOA-CNN-DNN model achieves statistically superior performance over contemporary state-of-the-art approaches, with mean accuracy of 97.8%, sensitivity of 96.4%, specificity of 98.2%, and AUC-ROC of 0.982 averaged across all five datasets.

Authors

Institutions

Publication Details

Journal
Measurement Sensors
Published
2026-05-01
DOI
https://doi.org/10.1016/j.measen.2026.102006
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing glaucoma detection using hybrid deep-evolutionary framework from retinal images

Shubhra Dwivedi, Tejasya Vashisht, Vikash Kumar Singh, Alok Kumar Shukla
Measurement Sensors
Retinal Imaging and Analysis
article

Optimizing glaucoma detection using hybrid deep-evolutionary framework from retinal images

Shubhra Dwivedi, Tejasya Vashisht, Vikash Kumar Singh, Alok Kumar Shukla
article en

Abstract

Glaucoma represents a heterogeneous group of progressive optic neuropathies characterized by the irreversible degeneration of retinal ganglion cells and their axons, culminating in structural optic nerve head damage and permanent visual field loss. Early and accurate detection is critical for preventing permanent vision loss, yet existing automated systems suffer from inadequate generalization across diverse datasets, poor handling of class imbalance, and sub-optimal hyperparameter selection in deep learning pipelines.To address these critical clinical challenges, this research proposes a novel hybrid evolutionary-optimized deep learning framework that systematically integrates Grasshopper Optimization Algorithm (GOA) with a custom CNN-DNN architecture specifically designed for glaucoma detection from fundus images.Unlike existing approaches that rely on manual or grid-based hyperparameter tuning, our GOA-based optimization systematically navigates a 7-dimensional hyperparameter space comprising learning rate, batch size, dropout rate, number of convolutional filters, dense layer units, regularization coefficient, and optimizer types. The proposed framework is rigorously evaluated across five publicly available benchmark datasets (RIM-ONE, ACRIMA, REFUGE, ORIGA, and DRISHTI-GS) representing diverse imaging protocols, patient demographics, and class distributions. Comprehensive statistical validation using Friedman test demonstrates that the GOA-CNN-DNN model achieves statistically superior performance over contemporary state-of-the-art approaches, with mean accuracy of 97.8%, sensitivity of 96.4%, specificity of 98.2%, and AUC-ROC of 0.982 averaged across all five datasets.

Measurement Sensors
Thapar Institute of Engineering & Technology (IN), SRM University (IN), VIT-AP University
Openalex Percentile: Top 6%
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.