Sentinel lymph node detection in melanoma: indocyanine green fluorescence compared with conventional mapping techniques

Accurate sentinel lymph node (SLN) mapping is essential for staging melanoma and guiding adjuvant therapy. Conventional mapping uses technetium-99m (Tc-99m) radiocolloid ± blue dye. Near-infrared fluorescence with indocyanine green (ICG) offers real-time, radiation-free visualization but varies in transcutaneous performance. This review synthesizes contemporary evidence comparing ICG to Tc-99m and blue dye for SLN detection in melanoma, highlighting anatomic, technical, and safety considerations relevant to surgical workflow. Narrative review of prospective series, head-to-head studies, and recent systematic reviews/meta-analyses evaluating SLN identification rates, node-level detection, transcutaneous vs. intraoperative fluorescence, false-negative considerations, and adverse events, with special attention to head/neck melanoma and dual-tracer strategies. ICG achieves high patient-level SLN identification (≈79-100%), comparable to Tc-99m (≈86-100%) and consistently superior to blue dye alone. Dual-tracer approaches (ICG + Tc-99m or ICG + blue dye) frequently report near-universal detection and practical reductions in missed nodes. Transcutaneous fluorescence through intact skin is variable, limited by near-infrared penetration and BMI, whereas intraoperative fluorescence after a small incision is highly reliable and expedites dissection. Head/neck basins particularly benefit from real-time fluorescence to delineate complex channels and confirm first-echelon nodes. ICG demonstrates an excellent safety profile with rare hypersensitivity, avoids radiation exposure, and integrates smoothly with gamma-probe guidance. Adoption barriers include heterogeneous dosing/timing, equipment cost, and lack of standardized reporting. ICG fluorescence is a robust adjunct to standard SLN mapping, offering intraoperative "visual GPS" especially valuable in head/neck melanoma. Current evidence supports ICG as a complement for radiocolloid mapping.

Authors

Institutions

Publication Details

Journal
Melanoma Research
Published
2026-05-11
DOI
https://doi.org/10.1097/cmr.0000000000001104
Primary Topic
Cutaneous Melanoma Detection and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sentinel lymph node detection in melanoma: indocyanine green fluorescence compared with conventional mapping techniques

Sahar Borna, Yu Zhang, Rajendra Saw-Martinez
Melanoma Research
Cutaneous Melanoma Detection and Management
article

Sentinel lymph node detection in melanoma: indocyanine green fluorescence compared with conventional mapping techniques

Sahar Borna, Yu Zhang, Rajendra Saw-Martinez
article en

Abstract

Accurate sentinel lymph node (SLN) mapping is essential for staging melanoma and guiding adjuvant therapy. Conventional mapping uses technetium-99m (Tc-99m) radiocolloid ± blue dye. Near-infrared fluorescence with indocyanine green (ICG) offers real-time, radiation-free visualization but varies in transcutaneous performance. This review synthesizes contemporary evidence comparing ICG to Tc-99m and blue dye for SLN detection in melanoma, highlighting anatomic, technical, and safety considerations relevant to surgical workflow. Narrative review of prospective series, head-to-head studies, and recent systematic reviews/meta-analyses evaluating SLN identification rates, node-level detection, transcutaneous vs. intraoperative fluorescence, false-negative considerations, and adverse events, with special attention to head/neck melanoma and dual-tracer strategies. ICG achieves high patient-level SLN identification (≈79-100%), comparable to Tc-99m (≈86-100%) and consistently superior to blue dye alone. Dual-tracer approaches (ICG + Tc-99m or ICG + blue dye) frequently report near-universal detection and practical reductions in missed nodes. Transcutaneous fluorescence through intact skin is variable, limited by near-infrared penetration and BMI, whereas intraoperative fluorescence after a small incision is highly reliable and expedites dissection. Head/neck basins particularly benefit from real-time fluorescence to delineate complex channels and confirm first-echelon nodes. ICG demonstrates an excellent safety profile with rare hypersensitivity, avoids radiation exposure, and integrates smoothly with gamma-probe guidance. Adoption barriers include heterogeneous dosing/timing, equipment cost, and lack of standardized reporting. ICG fluorescence is a robust adjunct to standard SLN mapping, offering intraoperative "visual GPS" especially valuable in head/neck melanoma. Current evidence supports ICG as a complement for radiocolloid mapping.

Melanoma Research
University of Central Florida (US), AdventHealth for Children (US), Florida College (US)
Openalex Percentile: Top 8%
Cutaneous Melanoma Detection and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.