Real‐time, high‐precision detection of aortic dissection key components for emergency triage using an enhanced deep learning model

BACKGROUND: Aortic dissection (AD) is a life-threatening cardiovascular emergency. For Type B AD (TBAD), rapid and accurate identification of the true lumen (TL), false lumen (FL), and false lumen thrombus (FLT) from CTA is critical for risk stratification and treatment planning. However, existing deep learning solutions often lack real-time capability and fail to address the detection of FLT. PURPOSE: To develop a real-time, high-precision deep learning framework for the simultaneous detection of all three key AD components to support emergency triage. METHODS: We propose AD-YOLO11, an enhanced YOLOv11 model integrating three key innovations: (1) a Recursive Information Distillation Network (RIDNet) for CTA noise suppression, (2) a Triplet Attention Mechanism for spatial and channel feature enhancement, and (3) the MPDIoU loss function for optimized bounding box regression. The model was trained and internally validated on a dataset of 25 176 slices from 106 TBAD patients and externally validated on 18 238 slices from 71 independent patients. RESULTS: On internal validation, AD-YOLO11 achieved a precision of 0.991 ± 0.004, recall of 0.936 ± 0.006, [email protected] of 0.951 ± 0.007, and [email protected]:0.95 of 0.883 ± 0.008. It maintained high performance on the external test set, demonstrating strong generalizability. The inference speed was 3.18 ± 0.23 ms per slice on GPU, and it remained clinically feasible on CPU (53.15 ± 2.76 ms per slice). CONCLUSIONS: AD-YOLO11 achieves millisecond-level, high-accuracy detection of all three critical Type B aortic dissection components from CTA images. Its efficient inference on both GPU and CPU makes it a promising frontline tool for rapid triage in emergency and resource-limited settings, effectively complementing time-consuming 3D segmentation for aortic dissection assessment.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2026-05-01
DOI
https://doi.org/10.1002/mp.70461
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real‐time, high‐precision detection of aortic dissection key components for emergency triage using an enhanced deep learning model

Houde Wu, Li Guo, Ruiqing Xia, Jinghui Zhang et al.
Medical Physics
Aortic Disease and Treatment Approaches
article

Real‐time, high‐precision detection of aortic dissection key components for emergency triage using an enhanced deep learning model

Houde Wu, Li Guo, Ruiqing Xia, Jinghui Zhang, Qingzhao Cheng, Longshuang Wang, Fei Chen, Zelong Zhang
article en

Abstract

BACKGROUND: Aortic dissection (AD) is a life-threatening cardiovascular emergency. For Type B AD (TBAD), rapid and accurate identification of the true lumen (TL), false lumen (FL), and false lumen thrombus (FLT) from CTA is critical for risk stratification and treatment planning. However, existing deep learning solutions often lack real-time capability and fail to address the detection of FLT. PURPOSE: To develop a real-time, high-precision deep learning framework for the simultaneous detection of all three key AD components to support emergency triage. METHODS: We propose AD-YOLO11, an enhanced YOLOv11 model integrating three key innovations: (1) a Recursive Information Distillation Network (RIDNet) for CTA noise suppression, (2) a Triplet Attention Mechanism for spatial and channel feature enhancement, and (3) the MPDIoU loss function for optimized bounding box regression. The model was trained and internally validated on a dataset of 25 176 slices from 106 TBAD patients and externally validated on 18 238 slices from 71 independent patients. RESULTS: On internal validation, AD-YOLO11 achieved a precision of 0.991 ± 0.004, recall of 0.936 ± 0.006, [email protected] of 0.951 ± 0.007, and [email protected]:0.95 of 0.883 ± 0.008. It maintained high performance on the external test set, demonstrating strong generalizability. The inference speed was 3.18 ± 0.23 ms per slice on GPU, and it remained clinically feasible on CPU (53.15 ± 2.76 ms per slice). CONCLUSIONS: AD-YOLO11 achieves millisecond-level, high-accuracy detection of all three critical Type B aortic dissection components from CTA images. Its efficient inference on both GPU and CPU makes it a promising frontline tool for rapid triage in emergency and resource-limited settings, effectively complementing time-consuming 3D segmentation for aortic dissection assessment.

Medical PhysicsVol. 53(5)
Tianjin Normal University (CN), Dalian Medical University (CN), Tianjin Third Central Hospital (CN), Cell Technology (China) (HK), Tianjin International Joint Academy of Biomedicine (CN), Tianjin Fire Research Institute (CN), First Affiliated Hospital of Dalian Medical University (CN), Tianjin Medical University (CN)
Openalex Percentile: Top 6%
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.