Leveraging micro-disk array device for sensitive duloxetine detection in human urine

An innovative microdisk array (MDA)-based microextraction technique was developed for the quantification of duloxetine in human urine, followed by HPLC–UV determination. The MDA system introduces a reusable and miniaturized extraction format, where an array-type configuration enhances mass transfer efficiency while reducing both sample manipulation and solvent requirements. The device was constructed by concentrically positioning two C18 microdisks onto a stainless-steel spinal needle, secured with frit-based supports. The extraction procedure involved immersing the MDA in the aqueous sample for 40 min, followed by a short rinsing step with water and subsequent elution of the analyte using 750 μL of methanol. Experimental variables influencing both adsorption and desorption processes were thoroughly optimized. Under the selected conditions, the method exhibited a linear response within the concentration range of 25–500 ng/mL and a limit of detection of 15 ng/mL. Precision, evaluated as intra- and inter-day variability, remained below 3.1%, while accuracy, expressed as relative recovery, ranged between 102.4% and 118.1%. The greenness of the analytical procedure was evaluated using the MA index, confirming its low environmental impact. Finally, the applicability of the method was verified through successful analysis of human urine samples, demonstrating the potential of the MDA-based approach as an efficient and sustainable sample preparation strategy. • C18 MDA enables efficient DULO extraction with robust, adaptable performance. • Modular design allows multi-sorbent tuning for selective, flexible extraction. • Low solvent use, high reproducibility, and throughput support green bioanalysis.

Authors

Institutions

Publication Details

Journal
Journal of Chromatography B
Published
2026-05-01
DOI
https://doi.org/10.1016/j.jchromb.2026.125112
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Leveraging micro-disk array device for sensitive duloxetine detection in human urine

Constantinos K. Zacharis, Marianna Ntorkou, Antonia Kalagia
Journal of Chromatography B
Analytical chemistry methods development
article

Leveraging micro-disk array device for sensitive duloxetine detection in human urine

Constantinos K. Zacharis, Marianna Ntorkou, Antonia Kalagia
article en

Abstract

An innovative microdisk array (MDA)-based microextraction technique was developed for the quantification of duloxetine in human urine, followed by HPLC–UV determination. The MDA system introduces a reusable and miniaturized extraction format, where an array-type configuration enhances mass transfer efficiency while reducing both sample manipulation and solvent requirements. The device was constructed by concentrically positioning two C18 microdisks onto a stainless-steel spinal needle, secured with frit-based supports. The extraction procedure involved immersing the MDA in the aqueous sample for 40 min, followed by a short rinsing step with water and subsequent elution of the analyte using 750 μL of methanol. Experimental variables influencing both adsorption and desorption processes were thoroughly optimized. Under the selected conditions, the method exhibited a linear response within the concentration range of 25–500 ng/mL and a limit of detection of 15 ng/mL. Precision, evaluated as intra- and inter-day variability, remained below 3.1%, while accuracy, expressed as relative recovery, ranged between 102.4% and 118.1%. The greenness of the analytical procedure was evaluated using the MA index, confirming its low environmental impact. Finally, the applicability of the method was verified through successful analysis of human urine samples, demonstrating the potential of the MDA-based approach as an efficient and sustainable sample preparation strategy. • C18 MDA enables efficient DULO extraction with robust, adaptable performance. • Modular design allows multi-sorbent tuning for selective, flexible extraction. • Low solvent use, high reproducibility, and throughput support green bioanalysis.

Journal of Chromatography B
Aristotle University of Thessaloniki (GR)
Responsible consumption and production
Openalex Percentile: Top 7%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.