Concentration and recovery of nitrogen from municipal solid waste leachate by means of forward osmosis and membrane contactor

• Forward Osmosis concentrated the sample around 2 times in terms of NH 4 + . • The flat sheet membrane 0.2 microns was the optimal one in terms of J_NH 3 and k m . • Sulphuric acid and higher pH were the optimal experimental conditions. • Acid concentrations it was not a significant parameter. • Forward Osmosis and membrane contactor are more effective used by separate. Municipal Solid Waste Leachate (MSWL) is a liquid waste generated in the composting of municipal solid waste or in landfills. This waste has a high organic matter concentration and a very high nutrients content, particularly ammoniacal nitrogen representing both an environmental liability and a potential resource. This study evaluates the operational performance and limitations of forward osmosis (FO) and membrane contactor (MC) processes, applied independently and a sequentially, as a favourable solution for recovering ammoniacal nitrogen from real MSWL. On one hand, forward osmosis was tested using (NH 4 ) 2 SO 4 as draw solution to concentrate ammonium in the feed solution (FS) achieving ammonium concentration factors up to 1.76 times, with water fluxes between 2.9-7.9 L·m⁻²·h⁻¹ depending on feed composition. On the other hand, for MC experiments, ammonia fluxes up to 33.54 g·m⁻²·h⁻¹ were obtained using a 0.2 μm polytetrafluoroethylene (PTFE) flat-sheet membrane with 0.1 M H₂SO₄ at pH 11. The integration of FO and MC revealed performance limitations associated with increased ionic strength and potential fouling effects in preconcentrated streams. These findings provide a critical assessment of the applicability boundaries of FO–MC integration for nitrogen recovery from highly variable real MSWL.

Authors

Institutions

Publication Details

Journal
Chemical Engineering Journal Advances
Published
2026-05-01
DOI
https://doi.org/10.1016/j.ceja.2026.101242
Primary Topic
Membrane Separation Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Concentration and recovery of nitrogen from municipal solid waste leachate by means of forward osmosis and membrane contactor

Iván Puchol-Candel, José-Antonio Mendoza-Roca, María-José Luján-Facundo, Beatriz Cuartas-Uribe
Chemical Engineering Journal Advances
Membrane Separation Technologies
article

Concentration and recovery of nitrogen from municipal solid waste leachate by means of forward osmosis and membrane contactor

Iván Puchol-Candel, José-Antonio Mendoza-Roca, María-José Luján-Facundo, Beatriz Cuartas-Uribe
article en

Abstract

• Forward Osmosis concentrated the sample around 2 times in terms of NH 4 + . • The flat sheet membrane 0.2 microns was the optimal one in terms of J_NH 3 and k m . • Sulphuric acid and higher pH were the optimal experimental conditions. • Acid concentrations it was not a significant parameter. • Forward Osmosis and membrane contactor are more effective used by separate. Municipal Solid Waste Leachate (MSWL) is a liquid waste generated in the composting of municipal solid waste or in landfills. This waste has a high organic matter concentration and a very high nutrients content, particularly ammoniacal nitrogen representing both an environmental liability and a potential resource. This study evaluates the operational performance and limitations of forward osmosis (FO) and membrane contactor (MC) processes, applied independently and a sequentially, as a favourable solution for recovering ammoniacal nitrogen from real MSWL. On one hand, forward osmosis was tested using (NH 4 ) 2 SO 4 as draw solution to concentrate ammonium in the feed solution (FS) achieving ammonium concentration factors up to 1.76 times, with water fluxes between 2.9-7.9 L·m⁻²·h⁻¹ depending on feed composition. On the other hand, for MC experiments, ammonia fluxes up to 33.54 g·m⁻²·h⁻¹ were obtained using a 0.2 μm polytetrafluoroethylene (PTFE) flat-sheet membrane with 0.1 M H₂SO₄ at pH 11. The integration of FO and MC revealed performance limitations associated with increased ionic strength and potential fouling effects in preconcentrated streams. These findings provide a critical assessment of the applicability boundaries of FO–MC integration for nitrogen recovery from highly variable real MSWL.

Chemical Engineering Journal Advances
Universitat Politècnica de València (ES)
Openalex Percentile: Top 9%
Membrane Separation Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.