Robot-Assisted Dentistry: What the Evidence Supports and Which Outcomes Are Still Missing

Dentistry has rapidly adopted digitally planned workflows, supported by cone-beam computed tomography, intraoral scanning, and virtual planning, expanding computer-assisted implant surgery through static guides, dynamic navigation, and robotic guidance. However, dental robotics is used inconsistently, and conflating robotics with navigation or automation can obscure key mechanistic and safety differences. This narrative review aimed to provide a clinically grounded synthesis of dental robotics across specialties, with emphasis on workflow dependencies, outcome patterns, and translational constraints. A structured literature search was conducted up to March 2026 using PubMed, Embase, Scopus, and Web of Science. Evidence was synthesized thematically, prioritizing clinical outcomes like accuracy, complications, peri-implant parameters, survival, patient- or provider-reported outcomes, workflow data, and implementation considerations. The most mature clinical evidence concerns robot-assisted implant placement, in which high agreement between planned and achieved positions was observed. Yet, accuracy should be interpreted as workflow performance influenced by imaging, planning, registration, tracking stability, and intraoperative conditions. Comparative data suggest the clearest gains versus freehand placement, while early adoption may increase operative time due to added setup and verification steps. Outside implantology, robotics follows distinct trajectories, including robotic orthodontic archwire bending, aligner-related automation, and transoral robotic surgery in maxillofacial practice, underscoring the need to appraise domains using different outcome hierarchies. Restorative and prosthodontic applications are emerging, ranging from robot-guided tooth preparation for crowns, onlays, and veneers to laboratory robotics for manufacturing, yet these remain largely industrial. Across domains, a recurring limitation is the mismatch between commonly reported geometric accuracy endpoints and underreported clinically decisive outcomes, which include complications, patient-reported outcomes, long-term maintenance, and economic value. Cost remains a major barrier, and formal cost-effectiveness evidence is limited.

Authors

Publication Details

Journal
Cureus
Published
2026-05-10
DOI
https://doi.org/10.7759/cureus.108601
Primary Topic
Dental Research and COVID-19
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robot-Assisted Dentistry: What the Evidence Supports and Which Outcomes Are Still Missing

Hanan Al-Qahtani, Abdulaziz Alghamdi, Fahad Alsaeed, Almiqdad Dashti et al.
Cureus
Dental Research and COVID-19
article

Robot-Assisted Dentistry: What the Evidence Supports and Which Outcomes Are Still Missing

Hanan Al-Qahtani, Abdulaziz Alghamdi, Fahad Alsaeed, Almiqdad Dashti, Noura Alshahrani, Naza Muhyedin, Ghaith Alqahtani, Ali Almadluh, Abdulaziz Alharbi, Azhar Kutbi, Madawi Al-Qahtani, Feras Baqazi, Nawaf Aljameel, Ruba Alshehri, Aeshah Agili
article en

Abstract

Dentistry has rapidly adopted digitally planned workflows, supported by cone-beam computed tomography, intraoral scanning, and virtual planning, expanding computer-assisted implant surgery through static guides, dynamic navigation, and robotic guidance. However, dental robotics is used inconsistently, and conflating robotics with navigation or automation can obscure key mechanistic and safety differences. This narrative review aimed to provide a clinically grounded synthesis of dental robotics across specialties, with emphasis on workflow dependencies, outcome patterns, and translational constraints. A structured literature search was conducted up to March 2026 using PubMed, Embase, Scopus, and Web of Science. Evidence was synthesized thematically, prioritizing clinical outcomes like accuracy, complications, peri-implant parameters, survival, patient- or provider-reported outcomes, workflow data, and implementation considerations. The most mature clinical evidence concerns robot-assisted implant placement, in which high agreement between planned and achieved positions was observed. Yet, accuracy should be interpreted as workflow performance influenced by imaging, planning, registration, tracking stability, and intraoperative conditions. Comparative data suggest the clearest gains versus freehand placement, while early adoption may increase operative time due to added setup and verification steps. Outside implantology, robotics follows distinct trajectories, including robotic orthodontic archwire bending, aligner-related automation, and transoral robotic surgery in maxillofacial practice, underscoring the need to appraise domains using different outcome hierarchies. Restorative and prosthodontic applications are emerging, ranging from robot-guided tooth preparation for crowns, onlays, and veneers to laboratory robotics for manufacturing, yet these remain largely industrial. Across domains, a recurring limitation is the mismatch between commonly reported geometric accuracy endpoints and underreported clinically decisive outcomes, which include complications, patient-reported outcomes, long-term maintenance, and economic value. Cost remains a major barrier, and formal cost-effectiveness evidence is limited.

Cureus
Openalex Percentile: Top 3%
Dental Research and COVID-19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.