Tiny patients, big decisions: the optimal thermometer for newborns

Abstract Background The use of accurate thermometers is critical in young (aged <3 months old) infants given the significant risk of serious infection in this age group. Best practice guidelines recommend direct electronic thermometers (axilla or rectal) for infants aged <3 months. Infrared thermometers (forehead or tympanic) are inaccurate in this patient population. Families commonly use infrared devices, which are available from pharmacies. Aim The primary aim of this study was to investigate the recommendations made in community pharmacies regarding thermometers for use in newborn infants and secondarily, to understand why particular thermometers were recommended. Method A prospective, observational cross‐sectional ‘secret shopper’ study was conducted from July to September 2022. Researchers sought pharmacy advice regarding suitable thermometer use for a newborn from pharmacies located in Melbourne, Australia. Ethics approval was granted by the Royal Children's Hospital Melbourne Human Research Ethics Committee (Reference no: 72682) and the study conforms with the Australian National statement on ethical conduct in human research . Results From 122 pharmacies, the best‐practice recommendation (use of direct thermometer) was made 9.8% of the time. Infrared thermometers were recommended 84.4% of the time, regardless of pharmacy type, socioeconomic status of the pharmacy location or whether a pharmacist or retail assistant provided the advice. Conclusion Despite clinical guideline recommendations that direct devices should be used in infants aged <3 months, infrared thermometers were overwhelmingly recommended in this sample of pharmacies. This research demonstrated the need for improved education regarding best practice for measuring temperatures in newborns.

Authors

Institutions

Publication Details

Journal
Journal of Pharmacy Practice and Research
Published
2026-05-08
DOI
https://doi.org/10.1002/jppr.70066
Primary Topic
Pharmaceutical studies and practices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tiny patients, big decisions: the optimal thermometer for newborns

Sandy M Hopper, Caroline M. Kissane, Doris Tham, Eliza Zhang
Journal of Pharmacy Practice and Research
Pharmaceutical studies and practices
article

Tiny patients, big decisions: the optimal thermometer for newborns

Sandy M Hopper, Caroline M. Kissane, Doris Tham, Eliza Zhang
article en

Abstract

Abstract Background The use of accurate thermometers is critical in young (aged <3 months old) infants given the significant risk of serious infection in this age group. Best practice guidelines recommend direct electronic thermometers (axilla or rectal) for infants aged <3 months. Infrared thermometers (forehead or tympanic) are inaccurate in this patient population. Families commonly use infrared devices, which are available from pharmacies. Aim The primary aim of this study was to investigate the recommendations made in community pharmacies regarding thermometers for use in newborn infants and secondarily, to understand why particular thermometers were recommended. Method A prospective, observational cross‐sectional ‘secret shopper’ study was conducted from July to September 2022. Researchers sought pharmacy advice regarding suitable thermometer use for a newborn from pharmacies located in Melbourne, Australia. Ethics approval was granted by the Royal Children's Hospital Melbourne Human Research Ethics Committee (Reference no: 72682) and the study conforms with the Australian National statement on ethical conduct in human research . Results From 122 pharmacies, the best‐practice recommendation (use of direct thermometer) was made 9.8% of the time. Infrared thermometers were recommended 84.4% of the time, regardless of pharmacy type, socioeconomic status of the pharmacy location or whether a pharmacist or retail assistant provided the advice. Conclusion Despite clinical guideline recommendations that direct devices should be used in infants aged <3 months, infrared thermometers were overwhelmingly recommended in this sample of pharmacies. This research demonstrated the need for improved education regarding best practice for measuring temperatures in newborns.

Journal of Pharmacy Practice and Research
Royal Children's Hospital (AU), The University of Melbourne (AU), Sunshine Hospital (AU), Murdoch Children's Research Institute (AU), Mercy Hospital (US)
Openalex Percentile: Top 5%
Pharmaceutical studies and practices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.