Non‐invasive Reduction of Accessory Breast Fat Using Multilayer High‐Intensity Focused Ultrasound: A Quantitative Ultrasound‐Based Study

OBJECTIVES: Accessory breast tissue often presents as localized axillary subcutaneous fullness, presenting as a palpable soft-tissue bulge composed of adipose or glandular elements, causing mechanical discomfort and esthetic concern. While surgical excision remains effective, it ma result in scarring, postoperative pain, and risks of seroma/hematoma or contour irregularity, leading to growing interest in noninvasive approaches. The objective of the study is to investigate the effect of noninvasive high-intensity focused ultrasound (HIFU) on subcutaneous fat thickness in axillary accessory breast tissue. METHODS: and accessory breast fat. All participants underwent a single HIFU session using multiple focal depths of 4.5, 6.0, and 9.0 mm at operating frequencies of 4 and 2 MHz, with energy settings of 1.5-2.0 J per shot. Fat thickness was measured by ultrasound at baseline and 8 weeks. Secondary outcomes included investigator-rated Global Aesthetic Improvement Scale (GAIS) and patient satisfaction scores. RESULTS: Among the 28 participants who completed the 8-week follow-up, mean subcutaneous fat thickness decreased from 19.2 ± 3.4 mm at baseline to 15.8 ± 3.1 mm at 8 weeks. The mean paired reduction was 3.4 ± 1.6 mm (17.7%), which was statistically significant (95% CI, 2.8-4.0 mm; p = 1.1 × 10⁻¹¹). All participants showed GAIS improvement with high satisfaction. No serious adverse events were observed; mild and transient effects included transient thermal discomfort and localized erythema resolving within several hours to 2 days, and no cases of skin burn were identified. CONCLUSION: Non-invasive HIFU produced a measurable reduction of accessory breast fat with favorable esthetic outcomes and an acceptable safety profile.

Authors

Institutions

Publication Details

Journal
Journal of Ultrasound in Medicine
Published
2026-05-08
DOI
https://doi.org/10.1002/jum.70238
Primary Topic
Body Contouring and Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non‐invasive Reduction of Accessory Breast Fat Using Multilayer High‐Intensity Focused Ultrasound: A Quantitative Ultrasound‐Based Study

Benjamin Ascher, Olena Sydorchuk, Kyu‐Ho Yi, Sebastien Garson et al.
Journal of Ultrasound in Medicine
Body Contouring and Surgery
article

Non‐invasive Reduction of Accessory Breast Fat Using Multilayer High‐Intensity Focused Ultrasound: A Quantitative Ultrasound‐Based Study

Benjamin Ascher, Olena Sydorchuk, Kyu‐Ho Yi, Sebastien Garson, Yerin Park, Hugues Cartier
article en

Abstract

OBJECTIVES: Accessory breast tissue often presents as localized axillary subcutaneous fullness, presenting as a palpable soft-tissue bulge composed of adipose or glandular elements, causing mechanical discomfort and esthetic concern. While surgical excision remains effective, it ma result in scarring, postoperative pain, and risks of seroma/hematoma or contour irregularity, leading to growing interest in noninvasive approaches. The objective of the study is to investigate the effect of noninvasive high-intensity focused ultrasound (HIFU) on subcutaneous fat thickness in axillary accessory breast tissue. METHODS: and accessory breast fat. All participants underwent a single HIFU session using multiple focal depths of 4.5, 6.0, and 9.0 mm at operating frequencies of 4 and 2 MHz, with energy settings of 1.5-2.0 J per shot. Fat thickness was measured by ultrasound at baseline and 8 weeks. Secondary outcomes included investigator-rated Global Aesthetic Improvement Scale (GAIS) and patient satisfaction scores. RESULTS: Among the 28 participants who completed the 8-week follow-up, mean subcutaneous fat thickness decreased from 19.2 ± 3.4 mm at baseline to 15.8 ± 3.1 mm at 8 weeks. The mean paired reduction was 3.4 ± 1.6 mm (17.7%), which was statistically significant (95% CI, 2.8-4.0 mm; p = 1.1 × 10⁻¹¹). All participants showed GAIS improvement with high satisfaction. No serious adverse events were observed; mild and transient effects included transient thermal discomfort and localized erythema resolving within several hours to 2 days, and no cases of skin burn were identified. CONCLUSION: Non-invasive HIFU produced a measurable reduction of accessory breast fat with favorable esthetic outcomes and an acceptable safety profile.

Journal of Ultrasound in Medicine
Airbus (France) (FR), Seoul Medical Center (KR), Dr Youth Clinic (KR), Centre Hospitalier d'Arras (FR)
Affordable and clean energy
Openalex Percentile: Top 5%
Body Contouring and Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.