Dosimetric Impact and Correction of Lipiodol Deposition on Photon-Beam Radiotherapy for Hepatocellular Carcinoma Using a Novel Simulation Model

Purpose: To evaluate the influence of Lipiodol area on radiotherapy dose distribution in the photon-beam treatment planning system (TPS) and develop a new simulation model of Lipiodol deposition in patients with hepatocellular carcinoma (HCC). Patients and Materials: We developed a Lipiodol deposition simulation model (LDSM) using a Lipiodol-porcine liver mixture to simulate the Lipiodol area after transcatheter arterial chemoembolization (TACE). The dose calculated by the TPS (D TPS ) and the detected dose (D DET ) using 6 MV X-ray irradiation using different fractional doses (1– 10 Gy/f) delivered by flattening-filter (FF) or flattening-filter-free (FFF) beams were compared. The computed tomography (CT) images of 60 patients with HCC who had undergone TACE were retrospectively reviewed and subjected to relative electron density (RED) correction and dosimetric evaluation. The dose deviation was evaluated across different TPS platforms and calculation algorithms. Results: In the Pinnacle 3 TPS with the collapsed cone convolution algorithm, the LDSM revealed a dose underestimation due to Lipiodol area in the photon-beam TPS, with the dose deviation factor (δ) increasing with increasing Lipiodol concentration (p < 0.001). The effects of FF and FFF beams ranged from 0.3% to 4.3% and 0.5% to 5.7%, respectively, but dose deviation was not correlated with fractional dose. In patients’ re-evaluated radiotherapy plans, the prescription dose coverage of gross tumor volume improved by a mean of 3.42% ± 0.92% (range, 2.00– 4.99%). The 50% prescription dose coverage of normal liver increased by 0.72% ± 0.36% (range, 0– 1.3%), and the maximum dose (D MAX ) to gastrointestinal tissue increased by 183.22 ± 138.80 cGy (range, 2.00– 453.00 cGy). The shortest distance between the tumor and the gastrointestinal tissue was an independent predictor of gastrointestinal dosimetric deviation. Conclusion: After TACE, Lipiodol area has a clinically significant dosimetric effect leading to the TPS underestimating the gastrointestinal D MAX delivered by the photon-beam. The dosimetric deviations should be corrected, especially in the TPS with the convolution algorithm. Keywords: lipiodol area, radiotherapy, transcatheter arterial chemoembolization, dosimetric correction

Authors

Institutions

Publication Details

Journal
Journal of Hepatocellular Carcinoma
Published
2026-05-01
DOI
https://doi.org/10.2147/jhc.s593372
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dosimetric Impact and Correction of Lipiodol Deposition on Photon-Beam Radiotherapy for Hepatocellular Carcinoma Using a Novel Simulation Model

Y Li, S Wang, Mengyuan Li, Kaixuan Zhang et al.
Journal of Hepatocellular Carcinoma
Advanced Radiotherapy Techniques
article

Dosimetric Impact and Correction of Lipiodol Deposition on Photon-Beam Radiotherapy for Hepatocellular Carcinoma Using a Novel Simulation Model

Y Li, S Wang, Mengyuan Li, Kaixuan Zhang, Kuo Men, Bo Chen, Ying Cao, Zhen Wang, Xiaowu Zhang, Wei Sun, Chenlei Guo, Yuan Tang, Xin Feng, Wei Zhang, Dong Yan, Yirui Zhai
article en

Abstract

Purpose: To evaluate the influence of Lipiodol area on radiotherapy dose distribution in the photon-beam treatment planning system (TPS) and develop a new simulation model of Lipiodol deposition in patients with hepatocellular carcinoma (HCC). Patients and Materials: We developed a Lipiodol deposition simulation model (LDSM) using a Lipiodol-porcine liver mixture to simulate the Lipiodol area after transcatheter arterial chemoembolization (TACE). The dose calculated by the TPS (D TPS ) and the detected dose (D DET ) using 6 MV X-ray irradiation using different fractional doses (1– 10 Gy/f) delivered by flattening-filter (FF) or flattening-filter-free (FFF) beams were compared. The computed tomography (CT) images of 60 patients with HCC who had undergone TACE were retrospectively reviewed and subjected to relative electron density (RED) correction and dosimetric evaluation. The dose deviation was evaluated across different TPS platforms and calculation algorithms. Results: In the Pinnacle 3 TPS with the collapsed cone convolution algorithm, the LDSM revealed a dose underestimation due to Lipiodol area in the photon-beam TPS, with the dose deviation factor (δ) increasing with increasing Lipiodol concentration (p < 0.001). The effects of FF and FFF beams ranged from 0.3% to 4.3% and 0.5% to 5.7%, respectively, but dose deviation was not correlated with fractional dose. In patients’ re-evaluated radiotherapy plans, the prescription dose coverage of gross tumor volume improved by a mean of 3.42% ± 0.92% (range, 2.00– 4.99%). The 50% prescription dose coverage of normal liver increased by 0.72% ± 0.36% (range, 0– 1.3%), and the maximum dose (D MAX ) to gastrointestinal tissue increased by 183.22 ± 138.80 cGy (range, 2.00– 453.00 cGy). The shortest distance between the tumor and the gastrointestinal tissue was an independent predictor of gastrointestinal dosimetric deviation. Conclusion: After TACE, Lipiodol area has a clinically significant dosimetric effect leading to the TPS underestimating the gastrointestinal D MAX delivered by the photon-beam. The dosimetric deviations should be corrected, especially in the TPS with the convolution algorithm. Keywords: lipiodol area, radiotherapy, transcatheter arterial chemoembolization, dosimetric correction

Journal of Hepatocellular CarcinomaVol. Volume 13
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), National Cancer Center (US)
Good health and well-being
Openalex Percentile: Top 5%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.