Validation of Rapid Gel-Clot Testing for the Detection of Bacterial Endotoxin in PET Radiopharmaceuticals with the Standard Cartridge Method- An Economical Solution for Routine Endotoxin Testing

Objectives: Endotoxin testing is mandatory for radiopharmaceuticals before human administration, as per the World Health Organisation (WHO) guidelines on the use of radiopharmaceuticals in humans. Bacterial endotoxin testing (BET) is mostly performed using either the gel-clot or the chromogenic (cartridge) method. Material and Methods: In this study, we have validated the rapid gel clot method with the chromogenic (cartridge) method. We tested three radioactive [ 18F ]FDG samples (n = 3) and three decayed [ 18 F]FDG samples using both a rapid gel assay and a cartridge-based method. Different dilutions were prepared, and the samples were incubated at 37 °C for a pre-set time. Results: Both techniques yielded concordant results, and endotoxin was detected below the reference value in the radiopharmaceutical samples. Though the cartridge method was more sensitive and robust, the rapid gel technique requires accurate pipetting and handling. The rapid gel assay is user-friendly and economical for routine testing, especially in developing countries or smallscale facilities. Conclusion: The rapid gel assay can serve as an alternative for qualitatively testing endotoxin levels.

Authors

Institutions

Publication Details

Journal
Indian Journal of Nuclear Medicine
Published
2026-05-09
DOI
https://doi.org/10.25259/ijnm_26_2026
Primary Topic
Immune Response and Inflammation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of Rapid Gel-Clot Testing for the Detection of Bacterial Endotoxin in PET Radiopharmaceuticals with the Standard Cartridge Method- An Economical Solution for Routine Endotoxin Testing

Deeksha Muralidhar, Pardeep Kumar, Sai Teja RB
Indian Journal of Nuclear Medicine
Immune Response and Inflammation
article

Validation of Rapid Gel-Clot Testing for the Detection of Bacterial Endotoxin in PET Radiopharmaceuticals with the Standard Cartridge Method- An Economical Solution for Routine Endotoxin Testing

Deeksha Muralidhar, Pardeep Kumar, Sai Teja RB
article en

Abstract

Objectives: Endotoxin testing is mandatory for radiopharmaceuticals before human administration, as per the World Health Organisation (WHO) guidelines on the use of radiopharmaceuticals in humans. Bacterial endotoxin testing (BET) is mostly performed using either the gel-clot or the chromogenic (cartridge) method. Material and Methods: In this study, we have validated the rapid gel clot method with the chromogenic (cartridge) method. We tested three radioactive [ 18F ]FDG samples (n = 3) and three decayed [ 18 F]FDG samples using both a rapid gel assay and a cartridge-based method. Different dilutions were prepared, and the samples were incubated at 37 °C for a pre-set time. Results: Both techniques yielded concordant results, and endotoxin was detected below the reference value in the radiopharmaceutical samples. Though the cartridge method was more sensitive and robust, the rapid gel technique requires accurate pipetting and handling. The rapid gel assay is user-friendly and economical for routine testing, especially in developing countries or smallscale facilities. Conclusion: The rapid gel assay can serve as an alternative for qualitatively testing endotoxin levels.

Indian Journal of Nuclear MedicineVol. 0
National Institute of Mental Health and Neurosciences (IN), Vellore Institute of Technology University (IN)
Partnerships for the goals
Openalex Percentile: Top 7%
Immune Response and Inflammation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Validation of Rapid Gel-Clot Testing for the Detection of Bacterial Endotoxin in PET Radiopharmaceuticals with the Standard Cartridge Method- An Economical Solution for Routine Endotoxin Testing — Deeksha Muralidhar, Pardeep Kumar, et al. · Indian Journal of Nuclear Medicine (2026) | TGRS Research Map | TGRS