Multiple vertebrae improves precision in image-based bone marrow absorbed dose estimation in [177Lu]Lu–DOTATATE treatment

BACKGROUND: Lu]Lu-DOTATATE. Bone marrow absorbed dose estimates and their precision were analyzed based on the number of vertebrae included in the calculation. Additional evaluations were performed using both measured (Lung-Spine phantom with spherical inserts) and simulated (digital XCAT phantom) SPECT data, with noise levels matching patients' bone marrow. RESULTS: Increasing the number of vertebrae from one to six improved precision in absorbed doses, reducing the coefficient of variation (COV) from 34 to 6.2%. Only minor differences (0.1%) in bone marrow absorbed dose were observed when adjusting reconstruction parameters from 1 subset, 60 iterations, to 12 subsets, 5 iterations. In the Lung-Spine phantom, smaller volumes (4 mL) were more sensitive to noise than larger volumes (16 mL), with COVs of 36% and 17%, respectively, at 60 updates. In the XCAT phantom, a decrease in recovery was observed in vertebrae near high-uptake regions (L5: 0.63, L1: 0.29), at 60 updates at the highest noise level. CONCLUSION: Including multiple lesion-free vertebrae enhances precision in image-based bone marrow absorbed dose calculations. Nevertheless, careful selection of vertebrae is important, as closely located high-uptake areas can bias absorbed dose estimates. Applying partial volume correction could mitigate spill-out effects, further improving accuracy. Additionally, the minimal differences between reconstruction parameters suggest that bone marrow absorbed dose estimates remain stable across subset configurations.

Authors

Institutions

Publication Details

Journal
EJNMMI Physics
Published
2026-05-09
DOI
https://doi.org/10.1186/s40658-026-00882-4
Primary Topic
Radiopharmaceutical Chemistry and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multiple vertebrae improves precision in image-based bone marrow absorbed dose estimation in [177Lu]Lu–DOTATATE treatment

Tobias Rydèn, Katja Smits, Frida Westerbergh, Jens Hemmingsson et al.
EJNMMI Physics
Radiopharmaceutical Chemistry and Applications
article

Multiple vertebrae improves precision in image-based bone marrow absorbed dose estimation in [177Lu]Lu–DOTATATE treatment

Tobias Rydèn, Katja Smits, Frida Westerbergh, Jens Hemmingsson, Anna-Lena Theisen, Martijn van Essen, Johannes Tran-Gia, Johanna Svensson, Peter Bernhardt
article en

Abstract

BACKGROUND: Lu]Lu-DOTATATE. Bone marrow absorbed dose estimates and their precision were analyzed based on the number of vertebrae included in the calculation. Additional evaluations were performed using both measured (Lung-Spine phantom with spherical inserts) and simulated (digital XCAT phantom) SPECT data, with noise levels matching patients' bone marrow. RESULTS: Increasing the number of vertebrae from one to six improved precision in absorbed doses, reducing the coefficient of variation (COV) from 34 to 6.2%. Only minor differences (0.1%) in bone marrow absorbed dose were observed when adjusting reconstruction parameters from 1 subset, 60 iterations, to 12 subsets, 5 iterations. In the Lung-Spine phantom, smaller volumes (4 mL) were more sensitive to noise than larger volumes (16 mL), with COVs of 36% and 17%, respectively, at 60 updates. In the XCAT phantom, a decrease in recovery was observed in vertebrae near high-uptake regions (L5: 0.63, L1: 0.29), at 60 updates at the highest noise level. CONCLUSION: Including multiple lesion-free vertebrae enhances precision in image-based bone marrow absorbed dose calculations. Nevertheless, careful selection of vertebrae is important, as closely located high-uptake areas can bias absorbed dose estimates. Applying partial volume correction could mitigate spill-out effects, further improving accuracy. Additionally, the minimal differences between reconstruction parameters suggest that bone marrow absorbed dose estimates remain stable across subset configurations.

EJNMMI PhysicsVol. 13(1)
Sahlgrenska University Hospital (SE), Universitätsklinikum Würzburg (DE), University of Gothenburg (SE)
Göteborgs Universitet
Good health and well-being
Openalex Percentile: Top 7%
Radiopharmaceutical Chemistry and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.