Lacrimal caruncula thermography overestimates rectal temperature in horses: Influence of camera type and measurement distance

BACKGROUND: Rectal temperature (RT) is the gold standard for assessing body temperature in horses, but handling and welfare concerns limit its use. Thermography of the lacrimal caruncula (LC) has been proposed as a noncontact alternative, although its accuracy may be influenced by device characteristics and measurement distance. OBJECTIVES: To evaluate agreement between LC thermography and RT in horses, compare two infrared thermal cameras and determine the effect of camera-to-subject distance on measurement bias and variability. METHODS: LC temperature was recorded at 0.5, 1 and 2 using two cameras (IR FlexCam S and UNI-T UTi165A). Eighty-four healthy Thoroughbreds contributed three measurements per camera. Agreement between LC and RT was evaluated using Bland-Altman analysis (bias and limits of agreement, LoA). Linear regression of the difference versus mean temperature assessed proportional bias. RESULTS: Both cameras produced higher LC values than RT at all distances, and agreement decreased as distance increased. For FlexCam, biases were 3.75°C at 0.5 m, 3.71°C at 1 m and 5.28°C at 2 m. LoA widened from 1.06-6.44°C at 0.5 m to 1.23-9.33°C at 2 m. For UTi165A, biases were 2.97°C at 0.5 m, 3.85°C at 1 m and 5.21°C at 2 m, with LoA from 0.86-5.08°C at 0.5 m to 2.04-8.39°C at 2 m. Negative regression slopes indicated proportional bias for both devices. MAIN LIMITATIONS: The indoor setting, evaluation of a single anatomical site and inclusion of only healthy Thoroughbreds limit generalisability. Only two camera systems were assessed. CONCLUSION: UTi165A showed narrower LoA and better repeatability at 0.5 m but did not demonstrate agreement sufficient to replace RT. Short acquisition distances, device selection and standardised protocols are essential if LC thermography is to be used as a screening adjunct in equine practice.

Authors

Institutions

Publication Details

Journal
Equine Veterinary Journal
Published
2026-05-09
DOI
https://doi.org/10.1002/evj.70174
Primary Topic
Veterinary Equine Medical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lacrimal caruncula thermography overestimates rectal temperature in horses: Influence of camera type and measurement distance

Ferda Turgut, Ömer Tarık Orhun, Sıtkıcan Okur, Latif Emrah Yanmaz et al.
Equine Veterinary Journal
Veterinary Equine Medical Research
article

Lacrimal caruncula thermography overestimates rectal temperature in horses: Influence of camera type and measurement distance

Ferda Turgut, Ömer Tarık Orhun, Sıtkıcan Okur, Latif Emrah Yanmaz, Taner Arslan
article en

Abstract

BACKGROUND: Rectal temperature (RT) is the gold standard for assessing body temperature in horses, but handling and welfare concerns limit its use. Thermography of the lacrimal caruncula (LC) has been proposed as a noncontact alternative, although its accuracy may be influenced by device characteristics and measurement distance. OBJECTIVES: To evaluate agreement between LC thermography and RT in horses, compare two infrared thermal cameras and determine the effect of camera-to-subject distance on measurement bias and variability. METHODS: LC temperature was recorded at 0.5, 1 and 2 using two cameras (IR FlexCam S and UNI-T UTi165A). Eighty-four healthy Thoroughbreds contributed three measurements per camera. Agreement between LC and RT was evaluated using Bland-Altman analysis (bias and limits of agreement, LoA). Linear regression of the difference versus mean temperature assessed proportional bias. RESULTS: Both cameras produced higher LC values than RT at all distances, and agreement decreased as distance increased. For FlexCam, biases were 3.75°C at 0.5 m, 3.71°C at 1 m and 5.28°C at 2 m. LoA widened from 1.06-6.44°C at 0.5 m to 1.23-9.33°C at 2 m. For UTi165A, biases were 2.97°C at 0.5 m, 3.85°C at 1 m and 5.21°C at 2 m, with LoA from 0.86-5.08°C at 0.5 m to 2.04-8.39°C at 2 m. Negative regression slopes indicated proportional bias for both devices. MAIN LIMITATIONS: The indoor setting, evaluation of a single anatomical site and inclusion of only healthy Thoroughbreds limit generalisability. Only two camera systems were assessed. CONCLUSION: UTi165A showed narrower LoA and better repeatability at 0.5 m but did not demonstrate agreement sufficient to replace RT. Short acquisition distances, device selection and standardised protocols are essential if LC thermography is to be used as a screening adjunct in equine practice.

Equine Veterinary Journal
Necmettin Erbakan University (TR), Burdur Mehmet Akif Ersoy Üniversitesi (TR), Cukurova University (TR), Atatürk University (TR)
Openalex Percentile: Top 6%
Veterinary Equine Medical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.