Ultrasound gap measurement after acute Achilles rupture is reliable overall but uncertain near a 5—mm decision threshold

OBJECTIVE: Ultrasound gap distance has been proposed as a supportive triage input within protocol-based pathways after acute Achilles tendon rupture. We assessed intra-/inter-rater reliability of gap measurement and the extent of classification uncertainty around a 5-mm threshold. Retrospective observer-agreement study without a definitive reference standard, using protocol-acquired stored ultrasound cine loops from 30 clinically diagnosed complete acute ruptures in a prospectively collected cohort. METHODS: Retrospective observer-agreement study without a definitive reference standard, using protocol-acquired stored ultrasound cine loops from 30 clinically diagnosed complete acute ruptures in a prospectively collected cohort. Two blinded musculoskeletal radiologists re-reviewed stored cine loops and measured tendon-gap distance in two sessions each (≥ 4 weeks apart). We calculated intraclass correlation coefficients (ICC), Bland-Altman mean difference and 95% limits of agreement (LoA), and standard error of measurement (SEM). Agreement at the 5-mm protocol cut-point was assessed using Cohen's κ and Gwet's AC1. Using SEM, we derived 90% confidence zones indicating firm classification versus a grey zone where repeat measurement or second read may be considered. RESULTS: Intra-rater ICC(2,1) was 0.88 (95% CI 0.83-0.91) and 0.94 (0.82-0.97); SEMs were 1.57 and 1.19 mm. Inter-rater bias was + 1.12 mm with LoA - 3.85 to 6.10 mm. Agreement for study experimental pathway classification at the 5-mm cut-point (operative vs non-operative) was moderate (κ = 0.60; AC1 = 0.61), with 6/30 examinations classified differently. SEM-based 90% zones were ≤ 2.42 and ≥ 7.58 mm (rater 1) and ≤ 3.04 and ≥ 6.96 mm (rater 2); a conservative cross-rater rule suggested ≤ 2.05 or ≥ 7.95 mm. CONCLUSION: Gap measurement shows good relative reliability, but uncertainty near 5 mm can alter classification. Reporting LoA/SEM alongside ICC and flagging a grey zone may reduce misclassification in borderline cases.

Authors

Institutions

Publication Details

Journal
Skeletal Radiology
Published
2026-05-08
DOI
https://doi.org/10.1007/s00256-026-05243-x
Primary Topic
Tendon Structure and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasound gap measurement after acute Achilles rupture is reliable overall but uncertain near a 5—mm decision threshold

Paweł Szaro, Dan Mocanu, Katarina Nilsson Helander, Elin Larsson et al.
Skeletal Radiology
Tendon Structure and Treatment
article

Ultrasound gap measurement after acute Achilles rupture is reliable overall but uncertain near a 5—mm decision threshold

Paweł Szaro, Dan Mocanu, Katarina Nilsson Helander, Elin Larsson, Katarzyna Bokwa‐Dąbrowska
article en

Abstract

OBJECTIVE: Ultrasound gap distance has been proposed as a supportive triage input within protocol-based pathways after acute Achilles tendon rupture. We assessed intra-/inter-rater reliability of gap measurement and the extent of classification uncertainty around a 5-mm threshold. Retrospective observer-agreement study without a definitive reference standard, using protocol-acquired stored ultrasound cine loops from 30 clinically diagnosed complete acute ruptures in a prospectively collected cohort. METHODS: Retrospective observer-agreement study without a definitive reference standard, using protocol-acquired stored ultrasound cine loops from 30 clinically diagnosed complete acute ruptures in a prospectively collected cohort. Two blinded musculoskeletal radiologists re-reviewed stored cine loops and measured tendon-gap distance in two sessions each (≥ 4 weeks apart). We calculated intraclass correlation coefficients (ICC), Bland-Altman mean difference and 95% limits of agreement (LoA), and standard error of measurement (SEM). Agreement at the 5-mm protocol cut-point was assessed using Cohen's κ and Gwet's AC1. Using SEM, we derived 90% confidence zones indicating firm classification versus a grey zone where repeat measurement or second read may be considered. RESULTS: Intra-rater ICC(2,1) was 0.88 (95% CI 0.83-0.91) and 0.94 (0.82-0.97); SEMs were 1.57 and 1.19 mm. Inter-rater bias was + 1.12 mm with LoA - 3.85 to 6.10 mm. Agreement for study experimental pathway classification at the 5-mm cut-point (operative vs non-operative) was moderate (κ = 0.60; AC1 = 0.61), with 6/30 examinations classified differently. SEM-based 90% zones were ≤ 2.42 and ≥ 7.58 mm (rater 1) and ≤ 3.04 and ≥ 6.96 mm (rater 2); a conservative cross-rater rule suggested ≤ 2.05 or ≥ 7.95 mm. CONCLUSION: Gap measurement shows good relative reliability, but uncertainty near 5 mm can alter classification. Reporting LoA/SEM alongside ICC and flagging a grey zone may reduce misclassification in borderline cases.

Skeletal Radiology
Sahlgrenska University Hospital (SE), University of Gothenburg (SE)
Peace, Justice and strong institutions
Openalex Percentile: Top 5%
Tendon Structure and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.