Digital Reference Frame Anchored to the Pedicle Screw–rod Construct for O-arm–Assisted Pedicle Screw Insertion: A Pilot Study

Objective: Accurate pedicle screw placement reduces neurological injury and complications. Although O-arm navigation improves precision, navigation error and digital reference frame (DRF) instability persist. This study aims to develop and evaluate a novel DRF anchored to the pedicle screw–rod construct as an alternative to spinous process–based attachment for O-arm–assisted pedicle screw insertion. Materials and Methods: This pilot study enrolled patients undergoing O-arm–assisted thoracolumbar pedicular screw instrumentation between November 2024 and February 2025. At each instrumented level, one pedicle screw was placed using the conventional DRF, and the contralateral pedicle screw was placed using the novel pedicle screw–rod–anchored DRF. We compared the 2 DRF systems within each level. Navigational error was defined as the angular deviation between the intraoperative virtual trajectory and the screw position on postoperative computed tomography. Pedicle breaches were identified and graded. Results: Twenty-two patients (110 pedicle screws) were included. The median navigational error did not differ between novel and conventional DRF in axial (2°, P = 0.500) or sagittal (2°, P = 0.070) planes. Subgroup analyses by level and pathology (degenerative, tumor, trauma) showed no significant differences. Minor pedicle breaches (< 2 mm) occurred in 2 screws with the novel DRF and 3 screws with the conventional DRF, all mid-thoracic and without clinical complications. Conclusions: The novel pedicle screw–rod–anchored DRF provides navigational accuracy comparable to the conventional system. These findings support its feasibility as an alternative reference frame for O-arm–guided spinal procedures when spinous process fixation is limited.

Authors

Institutions

Publication Details

Journal
DOAJ (DOAJ: Directory of Open Access Journals)
Published
2026-05-01
DOI
https://doi.org/10.33192/smj.v78i5.278286
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Digital Reference Frame Anchored to the Pedicle Screw–rod Construct for O-arm–Assisted Pedicle Screw Insertion: A Pilot Study

Monchai Ruangchainikom, Chatupon Chotigavanichaya, Ekkapoj Korwutthikulrangsri, Werasak Sutipornpalangkul et al.
DOAJ (DOAJ: Directory of Open Access Journals)
Spinal Fractures and Fixation Techniques
article

Digital Reference Frame Anchored to the Pedicle Screw–rod Construct for O-arm–Assisted Pedicle Screw Insertion: A Pilot Study

Monchai Ruangchainikom, Chatupon Chotigavanichaya, Ekkapoj Korwutthikulrangsri, Werasak Sutipornpalangkul, Panya Luksanapruksa, Sirichai Wilartratsami, Korawish Mekariya, Chonlatid Ruangsangthong, Dollaporn Anopas
article en

Abstract

Objective: Accurate pedicle screw placement reduces neurological injury and complications. Although O-arm navigation improves precision, navigation error and digital reference frame (DRF) instability persist. This study aims to develop and evaluate a novel DRF anchored to the pedicle screw–rod construct as an alternative to spinous process–based attachment for O-arm–assisted pedicle screw insertion. Materials and Methods: This pilot study enrolled patients undergoing O-arm–assisted thoracolumbar pedicular screw instrumentation between November 2024 and February 2025. At each instrumented level, one pedicle screw was placed using the conventional DRF, and the contralateral pedicle screw was placed using the novel pedicle screw–rod–anchored DRF. We compared the 2 DRF systems within each level. Navigational error was defined as the angular deviation between the intraoperative virtual trajectory and the screw position on postoperative computed tomography. Pedicle breaches were identified and graded. Results: Twenty-two patients (110 pedicle screws) were included. The median navigational error did not differ between novel and conventional DRF in axial (2°, P = 0.500) or sagittal (2°, P = 0.070) planes. Subgroup analyses by level and pathology (degenerative, tumor, trauma) showed no significant differences. Minor pedicle breaches (< 2 mm) occurred in 2 screws with the novel DRF and 3 screws with the conventional DRF, all mid-thoracic and without clinical complications. Conclusions: The novel pedicle screw–rod–anchored DRF provides navigational accuracy comparable to the conventional system. These findings support its feasibility as an alternative reference frame for O-arm–guided spinal procedures when spinous process fixation is limited.

DOAJ (DOAJ: Directory of Open Access Journals)
Siriraj Hospital (TH), Mahidol University (TH)
Openalex Percentile: Top 6%
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.