Surgeon-Led Surgical Device Development Using Computer-Aided 3D Modeling

ObjectiveTo describe a surgeon-led workflow for developing customized surgical instruments using computer-aided design (CAD) software and to evaluate the clinical utility of the resulting devices.MethodsUnmet clinical needs in spine surgery were identified by the operating surgeon, who then created three-dimensional (3D) models of five surgical instruments (windowed reamer, retractor blade for retroperitoneal or extrapleural approach, protect-guider, disposable sharp hook and holder, and flexible-tip retractor) using Autodesk Fusion 360®. Patient CT or MRI data were imported to determine key dimensions. Draft 3D models were provided to sales representatives, who relayed them to manufacturers' engineers for assessment of manufacturability and refinement into production drawings. The finished instruments were used in clinical practice for at least 6 months. Three board-certified neurospine surgeons completed a structured usability survey (six Likert-scale items) and reported the frequency of use of each device in eligible cases.ResultsThe windowed reamer and flexible-tip retractor achieved the highest mean satisfaction scores (27.7 ± 1.5 and 27.6 ± 1.5), followed by the retroperitoneal/extrapleural retractor (26.7 ± 1.5). These three devices are now used in almost all relevant procedures, effectively replacing their conventional counterparts at our institution. In contrast, the protect-guider and the disposable sharp hook and holder showed lower satisfaction and remain in mixed use with existing instruments.ConclusionSurgeon-generated 3D CAD models can substantially improve communication with manufacturers, enabling rapid development of customized surgical instruments that address specific intraoperative needs and, in some cases, replace standard tools in routine practice. This approach offers a practical pathway for surgeons to translate unmet clinical needs into manufacturable designs that can be integrated into conventional approval processes.

Authors

Institutions

Publication Details

Journal
Surgical Innovation
Published
2026-05-08
DOI
https://doi.org/10.1177/15533506261451353
Primary Topic
Anatomy and Medical Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Surgeon-Led Surgical Device Development Using Computer-Aided 3D Modeling

Je Hoon Jeong, Moonyoung Chung, Junghoon Kang, Soobin Im et al.
Surgical Innovation
Anatomy and Medical Technology
article

Surgeon-Led Surgical Device Development Using Computer-Aided 3D Modeling

Je Hoon Jeong, Moonyoung Chung, Junghoon Kang, Soobin Im, Seung Hwan Yoon, Hae-Dong Jang
article en

Abstract

ObjectiveTo describe a surgeon-led workflow for developing customized surgical instruments using computer-aided design (CAD) software and to evaluate the clinical utility of the resulting devices.MethodsUnmet clinical needs in spine surgery were identified by the operating surgeon, who then created three-dimensional (3D) models of five surgical instruments (windowed reamer, retractor blade for retroperitoneal or extrapleural approach, protect-guider, disposable sharp hook and holder, and flexible-tip retractor) using Autodesk Fusion 360®. Patient CT or MRI data were imported to determine key dimensions. Draft 3D models were provided to sales representatives, who relayed them to manufacturers' engineers for assessment of manufacturability and refinement into production drawings. The finished instruments were used in clinical practice for at least 6 months. Three board-certified neurospine surgeons completed a structured usability survey (six Likert-scale items) and reported the frequency of use of each device in eligible cases.ResultsThe windowed reamer and flexible-tip retractor achieved the highest mean satisfaction scores (27.7 ± 1.5 and 27.6 ± 1.5), followed by the retroperitoneal/extrapleural retractor (26.7 ± 1.5). These three devices are now used in almost all relevant procedures, effectively replacing their conventional counterparts at our institution. In contrast, the protect-guider and the disposable sharp hook and holder showed lower satisfaction and remain in mixed use with existing instruments.ConclusionSurgeon-generated 3D CAD models can substantially improve communication with manufacturers, enabling rapid development of customized surgical instruments that address specific intraoperative needs and, in some cases, replace standard tools in routine practice. This approach offers a practical pathway for surgeons to translate unmet clinical needs into manufacturable designs that can be integrated into conventional approval processes.

Surgical Innovation
Inha University (KR), Soonchunhyang University (KR)
Openalex Percentile: Top 8%
Anatomy and Medical Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.